SECTION 2: CIRCUIT REQUIREMENTS
220V Single-Phase
220V Three-Phase
G9984 Only:
The Model G9984 has a 3 H.P., 1725 R.P.M.
motor which requires a 220V single-phase circuit.
The cord set included does not have a plug, as
the style of plug you require will depend upon
the type of service you currently have or plan to
install. The motor will safely draw about 16 amps
at 220V under load. If you operate the Model
G9984 on any circuit that is already close to
its capacity, it might blow a fuse or trip a circuit
breaker. However, if an unusual load does not
exist, and the circuit breaker still trips, have the
circuit inspected by a qualified electrician.
In preparing to connect the Model G9984 to your
existing or new circuit, it will be necessary to con-
nect a plug that matches your 220V receptacle. If
you will be installing a new receptacle and plug,
we recommend using a NEMA-style L6-20 plug
and outlet shown in
Figure 1.
The Model G9984 should be fused at 20 amps.
Do not attempt to modify an existing circuit by
replacing the circuit breaker with one rated for a
higher amperage than the plug, outlet and wir-
ing can handle. Make sure that existing electrical
wires are capable of handling a 20 amp current. If
you are unsure, seek the assistance of a qualified
electrician.
Figure 1.
NEMA-style L6-20 plug and outlet
.
Figure 2.
NEMA-style L15-20 plug and outlet
.
Grounding Prong
is Hooked
Current Carrying Prongs
L6-20 GROUNDED
LOCKING
RECEPTACLE
L6-20
LOCKING
PLUG
Grounding Prong
is Hooked
Current Carrying Prongs
GROUNDED
L15-30 RECEPTACLE
L15-30
PLUG
G9985 Only:
The Model G9985 has a 3 H.P., 1725 R.P.M.
motor which requires a 220V three-phase circuit.
The cord set enclosed does not have a plug, as
the style of plug you require will depend upon
the type of service you currently have or plan to
install. The motor will safely draw about 9 amps at
220V under load. If you operate the Model G9985
on any circuit that is already close to its capac-
ity, it might blow a fuse or trip a circuit breaker.
However, if an unusual load does not exist, and
the circuit breaker still trips, have the circuit
inspected by a qualified electrician.
In preparing to connect the Model G9985 to your
existing or new circuit, it will be necessary to con-
nect a plug that matches your 220V receptacle. If
you will be installing a new receptacle and plug,
we recommend using a NEMA-style L15-20 plug
and outlet shown in
Figure 2.
The Model G9985 should be fused at 20 amps.
Do not attempt to modify an existing circuit by
replacing the circuit breaker with one rated for a
higher amperage than the plug, outlet and wir-
ing can handle. Make sure that existing electrical
wires are capable of handling a 20 amp current. If
you are unsure, seek the assistance of a qualified
electrician.
Содержание G9984
Страница 29: ...G9984 G9985 Mfd Since 07 18 27...
Страница 31: ...G9984 G9985 Mfd Since 07 18 29...
Страница 35: ...G9984 G9985 Mfd Since 07 18 33...
Страница 37: ...G9984 G9985 Mfd Since 07 18 35...
Страница 39: ...G9984 G9985 Mfd Since 07 18 37 NOTES...
Страница 40: ...38 G9984 G9985 Mfd Since 07 18 NOTES...
Страница 44: ......