![Grizzly G1071 Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/grizzly/g1071/g1071_owners-manual_2267484013.webp)
Model G1071 (Mfd. Since 11/10)
-11-
4. Use wire nuts to connect wires as indicated
in
Figure 5. Twist wire nuts onto their respec-
tive wires and wrap them with electrical tape
so they will not come loose.
5. Close and secure motor junction box.
6. Install a 6-15 plug according to manufac-
turer's instructions. If plug manufacturer's
instructions are not available, NEMA stan-
dard 6-15 plug wiring is provided on
Page 32.
Ground
Rewired to 240V
Start
Capacitor
300MFD
125VAC
Figure 5. Motor rewired to 240V.
To Switch
The voltage conversion MUST be performed by
an electrician or qualified service personnel.
The voltage conversion procedure consists of
rewiring the motor and installing the correct plug.
A wiring diagram is provided on
Page 32 for your
reference.
IMPORTANT: If the diagram included on the
motor conflicts with the one on
Page 32, the
motor may have changed since the manual was
printed. Use the diagram provided on the motor
junction box instead.
Items Needed
Qty
•
Phillips Head Screwdriver #2 ..................... 1
•
Electrical Tape ............................ As Needed
•
Wire Nut (16 AWG x 3) ............................... 1
•
6-15 Plug .................................................... 1
•
Wire Cutters/Stripper .................................. 1
To convert Model G1071 to 240V:
1. DISCONNECT MACHINE FROM POWER!
2. Cut off existing 5-15 plug.
3. Open motor junction box, remove two wire
nuts indicated in
Figure 4, then disconnect
wires.
Figure 4. Inside motor junction box (motor pre-
wired to 120V).
Ground
Start
Capacitor
300MFD
125VAC
To Switch
Remove
Wire
Nuts and
Disconnect
Wires
Connect Wires
and Secure
with Nuts
Voltage Conversion
to 240V
Содержание G1071
Страница 40: ......