Model G0925 (Mfd. Since 02/20)
-27-
Quill & Column Surfaces
Oil Type .....Grizzly T23962 or ISO 68 Equivalent
Oil Amount ............................................Thin Coat
Lubrication Frequency ...........8 Hrs. of Operation
Move the spindle all the way down to access the
smooth surfaces of the quill. Adjust table height
as necessary to access entire length of column
(see
Figures 37–38). Clean both with mineral
spirits and shop rags.
Note: Avoid removing the grease from the column
and quill racks during cleaning.
After cleaning, allow mineral spirits to dry, then
apply a thin coat of oil to the surfaces.
Figure 38. Column surface locations.
Column
Surfaces
Figure 37. Quill surface.
Quill
Surface
After cleaning, allow mineral spirits to dry, then
use a brush to apply a thin coat of grease to the
rack teeth, then fully raise/lower quill to distribute
grease.
Quill Rack
Figure 39. Quill rack location.
Quill Rack & Pinion
Grease Type .....Grizzly T26419 or NLGI#2 Equiv
Grease Amount ....................................Thin Coat
Lubrication Frequency ......... 90 hrs. of Operation
Move spindle all the way down to gain full access
to quill rack (see
Figure 39), then clean teeth with
mineral spirits, shop rags, and a brush.
Содержание G0925
Страница 44: ......