![Grizzly G0609X Скачать руководство пользователя страница 47](http://html1.mh-extra.com/html/grizzly/g0609x/g0609x_manual-insert_2267141047.webp)
-32-
G0609 12" Parallelogram Jointer
Review the troubleshooting and procedures in this section to fix your machine if a problem develops. If you
need replacement parts or you are unsure of your repair skills, then feel free to call our Technical Support
at (570) 546-9663.
SECTION 7: SERVICE
Troubleshooting
Motor & Electrical
Symptom
Possible Cause
Possible Solution
Motor will not
start or fuses or
circuit breakers
blow.
1. Power supply circuit breaker is blown/tripped.
2. Plug/receptacle is at fault or wired incorrectly.
3. Start capacitor is at fault.
4. Thermal overload relay has tripped.
5. Motor is at fault.
6. Emergency stop button depressed.
7. Motor ON button is at fault.
8. Open circuit in motor or loose connections.
9. Short circuit in line cord or plug.
10. Circuit not adequate to handle load.
1. Ensure correct size for machine load (refer to
Page
10
); replace weak breaker.
2. Test for good contacts; correct the wiring.
3. Test/replace if faulty.
4. Unplug machine, open magnetic switch cover, turn
amperage dial on Thermal Protection Circuit Breaker
to a higher amperage setting.
5. Test/repair/replace.
6. Twist the emergency stop button to allow it to pop
out.
7. Replace faulty ON button.
8. Inspect all lead connections on motor for loose or
open connections.
9. Repair or replace cord or plug for damaged insula-
tion and shorted wires.
10. Install correct circuit breaker; reduce # of machines
running on that circuit (circuit overload).
Motor overheats. 1. Motor overloaded during operation.
2. Air circulation through the motor restricted.
1. Reduce load on motor; take lighter cuts.
2. Clean out motor to provide normal air circulation.
Motor stalls or
shuts off during
a cut.
1. Motor overloaded during operation.
2. Thermal overload protection tripped in mag-
netic switch.
3. Short circuit in motor or loose connections.
4. Circuit breaker tripped.
5. Motor is at fault.
1. Reduce load on motor; take lighter cuts.
2. Unplug machine, open magnetic switch cover, turn
amperage dial on Thermal Protection Circuit Breaker
to a higher amperage setting.
3. Repair or replace connections on motor for loose or
shorted terminals or worn insulation.
4. Install correct circuit breaker; reduce # of machines
running on that circuit (circuit overload).
5. Test/repair/replace motor.
Blade
slows
when
cutting,
makes squealing
noise.
1. V-belt loose.
2. V-belt worn out.
1. Tighten V-belt (
Page 43
)
.
2. Replace V-belt (
Page 43
)
.
Loud repetitious
noise
coming
from machine.
1. Pulley setscrews or keys are missing or
loose.
2. Motor fan is hitting the cover.
3. V-belts are damaged.
1. Inspect keys and setscrews. Replace or tighten if
necessary.
2. Replace dented fan cover; replace loose/damaged
fan.
3. Replace V-belts (
Page 43
)
.
Vibration when
running or cut-
ting.
1. Loose, dull or misajusted blades.
2. Damaged V-belt.
3. Worn cutterhead bearings.
1. Tighten or replace blades.
2. Replace.
3. Check/replace cutterhead bearings.
Table Column Sizes:
Symptom = 1.5"
Possible Cause = 2.48"
Possible Solution = 3.2061"
Table Column Sizes:
Symptom = 1.1"
Possible Cause = 2.88"
Possible Solution = 3.2061"
Содержание G0609X
Страница 5: ...Model G0609X 4 Jointer Breakdown...
Страница 9: ...Model G0609X 8 K K K K K K K Stand Breakdown...
Страница 15: ......
Страница 22: ...G0609 12 Parallelogram Jointer 7 SECTION 1 SAFETY...
Страница 23: ...8 G0609 12 Parallelogram Jointer...
Страница 28: ...G0609 12 Parallelogram Jointer 13 Hardware Recognition Chart...
Страница 46: ...G0609 12 Parallelogram Jointer 31 Maintenance Performed Approximate Hours Of Use Maintenance Log Date...
Страница 61: ...46 G0609 12 Parallelogram Jointer G0609 Wiring Diagram...
Страница 62: ...G0609 12 Parallelogram Jointer 47 Base Assembly Parts Breakdown...
Страница 66: ...G0609 12 Parallelogram Jointer 51 Stand Assembly Parts Breakdown...
Страница 70: ......
Страница 71: ......
Страница 72: ......
Страница 73: ......