-6-
G0550/G0551 15" Planer
The Model G0550/G0551 motor is wired to oper-
ate at 220V only. The planer motors draw the fol-
lowing amperage:
Amperage Draw
G0550 2 HP ..........................................12 Amps
G0551 3 HP ..........................................18 Amps
Use the following guidelines when choosing a cir-
cuit breaker (circuit breakers rated any higher are
not adequate to protect the circuit):
Circuit Breaker
G0550 ........................................15 Amp, 2 Pole
G0551 ........................................20 Amp, 2 Pole
Figure 1a.
NEMA 6-15 plug and receptacle.
Figure 1b.
NEMA L6-20 plug and receptacle.
We recommend using a NEMA-style 6-15 plug
and outlet with the G0550 as shown in
Figure 1a
and an L6-20 plug and outlet for the G0551 as
shown in
Figure 1b.
You may also “hard-wire”
the planer directly to your panel, provided you
place a disconnect near the machine. Check the
electrical codes in your area for specifics on
wiring requirements.
Plug-Type
Circuit Breaker
Amperage Draw
SECTION 3: CIRCUIT REQUIREMENTS
Содержание G0550/G0551
Страница 51: ...G0550 G0551 15 Planer 49 Gauge Block Measurements...