background image

H8151 230V Mini Welder

-7-

SECTION 2: CIRCUIT REQUIREMENTS

Circuit Requirements

Amperage Draw

The  Model  H8151  welder  draws  the  following 
amps under maximum load:

Draw at 220V ......................................... 24 Amps

Circuit Requirements

Connect your welder to a dedicated and grounded 
circuit that is rated for the amperage given below. 
Never replace a circuit breaker on an existing cir-
cuit with one of higher amperage without consult-
ing  a  qualified  electrician  to  ensure  compliance 
with wiring codes. 

If you are unsure about the 

wiring codes in your area or you plan to con-

nect your machine to a shared circuit, consult 

a qualified electrician.

Minimum 220V Circuit Requirement .....30 Amps

Plug/Receptacle Type

Recommended Plug/Receptacle ....NEMA L6-30

Serious  personal  injury  could  occur  if  you 

connect  the  machine  to  the  power  source 

before you have completed the set up pro-

cess.  DO  NOT  connect  the  machine  to  the 

power source until instructed to do so.

220V Operation

Grounding

In  the  event  of  an  electrical  short,  grounding 
reduces the risk of electric shock. The grounding 
wire in the power cord must be properly connected 
to the grounding prong on the plug; likewise, the 
outlet  must  be  properly  installed  and  grounded. 
All electrical connections must be made in accor-
dance with local codes and ordinances.

Electrocution or fire could 

result  if  this  machine  is 

not  grounded  correctly 

or  if  your  electrical  con-

figuration  does  not  com-

ply  with  local  and  state 

codes. Ensure compliance 

by  checking  with  a  quali-

fied electrician!

Extension Cords

We do not recommend the use of extension cords. 
Instead, arrange the placement of your equipment 
and the installed wiring to eliminate the need for 
extension cords.

If you find it absolutely necessary to use an exten-
sion cord at 220V with your machine:

• 

Use  at  least  a  10  gauge  cord  that  does  not 
exceed 50 feet in length.

• 

The  extension  cord  must  also  contain  a 
ground wire and plug pin.

• 

A qualified electrician MUST size cords over 
50 feet long to prevent motor damage.

Figure 3.

 NEMA L6-30 plug and receptacle.

Содержание 230V

Страница 1: ...NI WELDER OWNER S MANUAL COPYRIGHT MAY 2007 BY GRIZZLY INDUSTRIAL INC WARNING NO PORTION OF THIS MANUAL MAY BE REPRODUCED IN ANY SHAPE OR FORM WITHOUT THE WRITTEN APPROVAL OF GRIZZLY INDUSTRIAL INC TS9041 PRINTED IN CHINA ...

Страница 2: ... ...

Страница 3: ...tional Sources for Welding Codes and Standards 6 SECTION 2 CIRCUIT REQUIREMENTS 7 220V Operation 7 Grounding for Arc Welding Safety 8 SECTION 3 INVENTORY 9 SECTION 4 OPERATIONS 10 Operation Safety 10 Welder Duty Cycle 10 General Arc Welding Operations 11 SECTION 5 ACCESSORIES 12 SECTION 6 SERVICE 13 Troubleshooting 13 Replacement Parts And Labels 14 WARRANTY AND RETURNS 17 ...

Страница 4: ...n the part of Grizzly For your convenience we always keep current Grizzly manuals available on our website at www grizzly com Any updates to your machine will be reflected in these manuals as soon as they are complete Visit our site often to check for the lat est updates to this manual Contact Info If you have any comments regarding this manual please write to us at the address below Grizzly Indus...

Страница 5: ...tification A Electrode Holder and Cable B Negative Output Socket C Power Lamp D Temperature Warning Lamp E Carrying Strap F Variable Current Output Dial G Positive Output Socket H Work Clamp and Cable I Power Cord J ON OFF Switch K Cooling Fan and Cover L Welder Enclosure Ground Terminal Figure 1 Model H8151 front view C D F G B A H E Figure 2 Model H8151 rear view I L J K ...

Страница 6: ...zone and the general area Use ANSI approved respirators for the type of welding operation Protect others from these fumes 3 WELDING IN A CONFINED SPACE CAN BE HAZARDOUS Always open all covers sustain forced ventilation remove toxic and hazardous materials and provide a power disconnect to the welder inside the work space Always work with someone who can give you help from outside the space Welding...

Страница 7: ...ep lead cables orga nized and away from your body 8 AVOID EXPLOSION HAZARD Never weld on closed containers or containers with fumes inside Containers should be prepared per American Welding Society Publication F4 1 Section 7 8 ELECTRIC AND MAGNETIC FIELDS EMF Welding operations create EMF around the welding equipment and workpieces Workers who have pacemak ers must consult with their physician bef...

Страница 8: ...t P 1 Canadian Standards Association Standards Sales 178 Rexdale Boulevard Rexdale Ontario Canada M9W 1R3 800 463 6727 Website www csa international org Code for Safety in Welding and Cutting CSA Standard W117 2 American National Standards Institute ANSI 11 West 42nd Street New York NY 10036 8002 212 642 4900 Website www ansi org Practice for Occupational and Educational Eye and Face Protection AN...

Страница 9: ...ed to do so 220V Operation Grounding In the event of an electrical short grounding reduces the risk of electric shock The grounding wire in the power cord must be properly connected to the grounding prong on the plug likewise the outlet must be properly installed and grounded All electrical connections must be made in accor dance with local codes and ordinances Electrocution or fire could result i...

Страница 10: ...orkpiece Ground The incoming power circuit to the welder and the welding circuit are two separate circuits that must have separate grounds The welding circuit consists of the internal components of the welder the welding cables the electrode holder the work clamp and the workpiece In the publication Safety in Welding Cutting and Allied Processes ANSI Publication Z49 1 11 3 2 1 it is specified that...

Страница 11: ... the containers and all packing materials for possible inspection by the carrier or its agent Otherwise filing a freight claim can be difficult When you are completely satisfied with the condition of your shipment inventory the contents Figure 5 Model H8151 inventory C D E F G B H A A Polyurethane Carrying Case B Welder Carrying Strap C 230V Mini Welder D Work Clamp and Cable E Utility Brush and S...

Страница 12: ...ver heating each welder has an established duty cycle The duty cycle is vari able depending upon the amperage output being used A duty cycle is the number of minutes out of 10 minutes that the welder can safely operate at the current amperage output without over heating For instance the Model H8151 has a duty cycle of 60 at 95A output This means that the welder can operate continuously for 6 out o...

Страница 13: ...r stand by to assist if needed 4 Select the correct electrode type and size for your welding project 5 Choose the correct amperage output and be aware of the duty cycle for this amperage 6 Decide which type of weld is correct for your project and properly prepare the metal 7 Make sure the welding cables and grounds are secure Note Insert the welding cable connectors into the welder output sockets ...

Страница 14: ...for welding applications Special depth filter pro vides high loading capacity for metal fumes with out increasing breathing resistance Heavy duty adjustable headstrap and soft closed cell foam face seal offers maximum comfort protection and fit 5 pack Figure 7 Model G7868 welding respirators Figure 8 Models H9748 H9746 H9745 leather welding protection H9748 Leather Jacket Medium 40 42 H9887 Leathe...

Страница 15: ...arge electrode or decrease amperage 2 Reduce voltage or arc length 3 Use correct type and size of electrode Distortion of base metal 1 Excessive heat applied to base metal 1 Make tack welds along joint before starting opera tion select lower amperage for electrode increase travel speed weld in small segments and allow cool ing between welds Burn through or excessive penetra tion of base metal 1 Ex...

Страница 16: ...ntact Grizzly at 800 523 4777 or www grizzly com to order new labels Replacement Parts And Labels REF PART DESCRIPTION REF PART DESCRIPTION 1 PH8151001 POLYURETHANE CARRYING CASE 7 PH8151004 WELDERS MASK HANDLE 2 PH8151002 CARRYING STRAP 8 PLABEL 14 ELECTRICITY LABEL 3 PH8151003 WORK CLAMP CABLE 9 PH8151009 SHOCK HAZARD LABEL 4 PH8151007 UTILITY BRUSH PICK 10 PH8151010 MACHINE ID LABEL 5 PH8151008...

Страница 17: ... ...

Страница 18: ... ...

Страница 19: ...the State of Washington County of Whatcom We shall in no event be liable for death injuries to persons or property or for incidental contingent special or consequential damages arising from the use of our products To take advantage of this warranty contact us by mail or phone and give us all the details We will then issue you a Return Number which must be clearly posted on the outside as well as t...

Страница 20: ... ...

Отзывы: