background image

Parade

User Manual

 L1 - L2- L3 - L4

Rev. 4.0
Date: 29/09/2022

page 1 of 8

Griven

 S.r.l. - Via Bulgaria, 16

46042 Castel Goffredo
Mantova -  Italy

© Copyright Griven 2020 - GRIVEN S.r.l. is continuously 
developing and improving all its products. 
We reserve the right to change specifications without 
prior notification

Tel. +39.0376.779483
E-mail: [email protected]
Web: www.griven.com

551091

Parade L1

Parade L2

Parade L3

Parade L4

Code

AL5060 - AL5061 (PE)

AL5065 - AL5066 (PE)

AL5070 - AL5071 (PE)

AL5075 - AL5076  (PE)

Power consumption

Consumo di energia

20W (RN) 19W (DW) 

19W (W) 

38W (RN) 38W (DW) 

37W (W) 

58W (RN) 57W (DW) 

56W (W) 

79W (RN) 76W (DW) 

75W (W) 

Nominal current

Corrente nominale

0.1A (RN) 0.1A (DW) 

0.1A (W) @230Vac

0.17A (RN) 0.17A (DW) 

0.17A (W) @230Vac

0.26A (RN) 0.26A (DW) 

0.25A (W) @230Vac

0.35A (RN) 0.34A (DW) 

0.34A (W) @230Vac

Power supply

Alimentazione elettrica

220-240VAC 50/60Hz

Inrush current

Corrente di spunto

23.42 A @240VAC, 25°C

27.5 A @240VAC, 25°C

Power factor

Fattore di potenza

cos.

φ

= 0.87

cos.

φ

= 0.94

cos.

φ

= 0.95

cos.

φ

= 0.97

Electrical class

Classe elettrica

I

Weight / Peso

2.1 Kg

3.1 Kg

4.4 Kg

5.6 Kg

Operating temperature 

Temp. funzionamento

-40°C to +50°C ( -40°F to 122°F )

IP rating / Grado IP

IP67

IK rating / Grado IK

IK09

 914 mm [36”] 

 70 mm 

1219 mm [48”] 

 610 mm [24”] 

 318 mm 

 70 mm 

 76 mm 

 [12.5”] 

 [2.7”] 

 [3”] 

 [2.7”] 

Parade L1

Parade L2
Parade L3
Parade L4

Dimensions / Dimensioni

Содержание Parade L1

Страница 1: ...N 38W DW 37W W 58W RN 57W DW 56W W 79W RN 76W DW 75W W Nominal current Corrente nominale 0 1A RN 0 1A DW 0 1A W 230Vac 0 17A RN 0 17A DW 0 17A W 230Vac 0 26A RN 0 26A DW 0 25A W 230Vac 0 35A RN 0 34A...

Страница 2: ...l alimentazione prima di effettuare qualsiasi operazione all interno dell apparecchiatura Togliere l alimentazione prima di effettuare qualsiasi operazione di connessione tra gli apparecchi Prima di...

Страница 3: ...utral Brown L Line Yellow Green GND RED DMX BLACK DMX WHITE COMMON Blue N Neutral Brown L Line Yellow Green GND RED DMX BLACK DMX WHITE COMMON POWER DMX IN OUT POWER DMX IN OUT M Type cable Monocable...

Страница 4: ...n the projector is on if required by the weather conditions the glass is automatically warmed up WARNING If the projection is to be started at a definite time take care to defrost the glass in advance...

Страница 5: ...MATIC MODE TO BE USED ONLY WITH DMX MODE 1 AUTOMATIC MASTER 5 10 20 40 40 20 10 5 001 SLAVE FIXTURE SETTING OK FLASH FLASH FLASH FLASH 2x FLASH 3x FLASH 4x FLASH 4x FLASH 3x FLASH 2x FLASH FLASH FIXED...

Страница 6: ...251 255 6 No Strobo 0 5 0 100 Strobo 6 250 100 Strobo 251 255 4 IR 7 1 0 100 Red 0 255 2 0 100 Green 0 255 3 0 100 Blue 0 255 4 0 100 White 0 255 5 NO FUNCTION 0 5 2700K 6 7 2700K 3000K 8 40 3000K 41...

Страница 7: ...te 64 79 Store DTR as Scene 0 15 80 95 Remove from Scene 0 15 96 111 Add to Group 0 15 112 127 Remove from Group 0 15 128 Store DTR as Short Address 144 Query Status 145 Query Ballast 151 Query Versio...

Страница 8: ...ble AL8264 L 1m AL8265 L 2m AL8266 L 3m AL8267 L 5m AL8268 L 10m F DMX Terminator AL5169 G Repower Box AL5167C with connectos AL5167M without connectors H DMX Junction Box AL5059C with connectors AL50...

Отзывы: