5.1 Setting operating mode

By using the infrared remote control AL1321 it is possible to select one of the following operating mode.

• using DMX512 signal control mode

Each fixture is controlled from DMX512 signal control.

• MASTER-SLAVE or AUTOMATIC mode

The projector operates independently, without DMX512 signal control. (see chapter 8)

Every button push is confirmed by a very short flash coming from the projector.

The following buttons will be used:

5.2 Setting DMX Address

By using the remote control (AL1321) it is possible to select the DMX address and mode:

5.3 DMX address setting with the accessory Weezerd 1

The  DMX  address  can  be  set  only  by  using  the  accessory 

AL2660  Weezerd  1

.  Refer  to  the  manual  of  the 

accessory.

5.4 Setting DMX mode with the accessory Weezerd 1

The DMX mode can be set only by using the accessory 

AL2660 Weezerd 1

. Refer to the manual of the accessory.

5.0 Use of the unit

AV

TELETEXT

1-/--

AV

79ʗ

.....

1

0

PROG +

PROG -

P+

P-

Warning! 

Before performing any setting operation it is necessary to log in as reported in the chart below.

Function

Buttons

Description

LOGIN

1

2

3

It is the first procedure to be performed. After pushing the buttons 1, 2, 3  it is pos-

sible to access the functions settings. The function is confirmed by 1 white flash

coming from the projector.  

LOGOUT

/

The logout is automatic after 5 minutes of missing reception of the signal coming

from the remote control. Once th projector logs out it is not possible to perform

any other operation before a new login.

Funzione

Tasti

Descrizione

Change

of DMX

mode

+ 1 /.../ 6

Select the nuber of DMX channels. If the setting is correct then the projector will

confirm the procedure by performing 2 white flashes. (e.g. Projector RGBW 5

channels, press 5)

Change

of DMX

address

+  0....9 

79ʗ

The new entered address must feature 3 digits (e.g. 0 6 7). If the address is correct

then the projector will confirm the procedure by performing 3 white flashes

Содержание Jasper AL4360

Страница 1: ...Jasper AL4360 Manuale di istruzioni Instructions manual...

Страница 2: ...with DMX MODE 5 channels 21 5 5 3 DMX functions with DMX MODE 6 channels 21 5 6 DMX functions Dynamic white 22 5 6 1 DMX functions with DMX MODE 2 channels 22 5 6 2 DMX functions with DMX MODE 3 chann...

Страница 3: ...ied technician for any regular maintenance action not described in this manual 1 1 2 Installation The unit installation actions must be performed by a qualified staff 1 1 3 Protection against burns an...

Страница 4: ...19 1 2 495 17 3 4 450 18 3 4 477 3 1 8 80 5 5 8 142 15 4 3 4 120 3 8 1 0 5 0 1 4 6 5 0 1 4 6 5 0 3 0 Packaging and transport Warning Griven S r l liability will cease upon consignment of goods to the...

Страница 5: ...n operate in any position Use the holes 10 5 3 8 or 6 5 1 4 in the bracket to fix the unit 4 2 Adjusting light beam direction 1 Untighten the lateral screw 1 2 Rotate the bodies of the unit towards de...

Страница 6: ...supplies features are compatible with the unit features The unit must never be installed if not grounded electrically It is suggested to use a magnetothermic switch along the power supply line as pres...

Страница 7: ...er to the manual of the accessory 5 0 Use of the unit AV TELETEXT 1 AV 79 1 0 PROG PROG P P Warning Before performing any setting operation it is necessary to log in as reported in the chart below Fun...

Страница 8: ...olor 3 Blue 0 255 Proportional control 0 100 of the Blue color 4 White 0 255 Proportional control 0 100 of the White color 5 Dimmer Strobe 0 15 Luminous output intensity 100 16 150 Proportional contro...

Страница 9: ...160 Luminous output intensity 0 161 255 Proportional control of the strobe effect 0 100 255 max Channel Function Value Description 1 Warm white 0 255 Proportional control 0 100 of the warm white 2 Col...

Страница 10: ...ction RGBW and DW MASTER SLAVE 1 SLAVE N IN OUT IN OUT SLAVE 2 IN OUT Terminal resistor R 120 not included Funzione Tasti Descrizione Master Con figuration AV the input or the removing of the automati...

Страница 11: ...the TV key Colour se lection 1 2 3 4 Select the colour whose intensity is intended to be adjusted by the keys from 1 to 4 1 red 2 green 3 blue 4 white Colour intensity The intensity of the selected c...

Страница 12: ...to be started at a definite time take care to defrost the glass in advance so that the leds can be lit at the time required With very cold temperatures below 20 C we recommend you to let the projector...

Страница 13: ...sistance centres easier specify serial number and model of the unit which spare parts are requested for Inconvenience Possibile Cause Action The unit does not respond properly to the DMX control Incor...

Страница 14: ...ir old appliance Mechanical features Height 495mm 19 1 2 Width 477mm 18 3 4 Depth 142mm 5 5 8 Weight 18Kg 39 7Lbs Thermal features Minimum ambient temperature 40 C 40 F Maximum ambient temperature 50...

Страница 15: ...Bulgaria 16 46042 CASTEL GOFFREDO MN Italy Telefono 0376 779483 Fax 0376 779682 0376 779552 http www griven com e mail griven griven com http www griven it e mail griven griven it User s manual rel 1...