background image

AL4700 Graph-i-Dot - Rev. 1.00

page 4 of 12

551073

Connecting Graph-i-Dot to the Power supply ( KIT AL4704 ).

GND

A

B

AD

+VCC

GND

A

B

AD

+VCC

GND

A

B

AD

+VCC

GND

A

B

AD

+VCC

GREEN TIP 

RED TIP

RED TIP

24VCC from PSU

GREEN TIP 

GREEN TIP 

1

2

1

2

the internal ring must melt

the sleeve

must shrink

and adhere to

the cables

IN ORDER TO GUARANTEE IP67 FEATURES: 

 

4,50 

 

4,50 

 

4,50 

 13,69 

 13,69 

 41,94 

Description :

Revision :

Scale :

Code :

Weight :

Note :

 http://www.griven.com

1:1

SHEET 1 OF 1

Description :

Revision :

Scale :

Code :

Weight :

Note :

 http://www.griven.com

Copyright 

© 

2017 , GRIVEN S.r.l. World Lighting Challenge

 - 

1:1

SHEET 1 OF 1

The kit contains:

- 1 2 halves plastic enclosure with holes for eventual fixing.

- 3 IP67 thermo-shrinking terminal caps ( Green tip).

- 2 IP67 thermo-shrinking terminal caps ( Red tip).

Содержание Graph-i-Dot AL4700

Страница 1: ...om AL4700 Rev 1 00 Date 11 01 2019 page 1 of 12 Size Weight Peso 50 g 1 76 oz each Graph i Dot Housing Corpo proiettore Transparent plastic IK rating classe IK IK10 IP rating grado IP IP68 max 20 m Am...

Страница 2: ...for long periods Non lasciare mai per lungo tempo agli agenti atmosferici cavi e connettori non collegati o non protetti Disconnect power before installing or servicing to avoid electrical shock Togl...

Страница 3: ...evono obbligatoriamente essere eseguite solo da per sonale specializzato WARNING Ensure power supply is off before connecting or disconnecting fixtures ATTENZIONE Assicurarsi che l alimentazione sia d...

Страница 4: ...A B AD VCC GREEN TIP GREEN TIP 4 50 4 50 4 50 13 69 13 69 41 94 Weight Note http www griven com 1 1 1 OF 1 Weight Note http www griven com 1 1 1 OF 1 The kit contains 1 2 halves plastic enclosure with...

Страница 5: ...pical system diagram Graph i Dot chain 110 266 VAC 50 60Hz 110 266 VAC 50 60Hz DMX CONTROLLER AL4703 Start Line kit AL4704 Power joint Kit AL4705 Joint Kit AL4706 Terminator cap AL4704 Power joint Kit...

Страница 6: ...ring must melt the sleeve must shrink and adhere to the cables IN ORDER TO GUARANTEE IP67 FEATURES Place with care the cables into the lower half of the enclosure fix the joint caps in order to take u...

Страница 7: ...y before fixing it on to a surface Replacing a faulty Graph i Dot KIT AL4705 GND A B AD VCC GND A B AD VCC Remove the faulty Dot saving the more cable lenght possible Split the cables and strip the en...

Страница 8: ...er half over the lower half of the enclosure press until the lock of the clips GND A B AD VCC GND A B AD VCC Put before soldering each joint the thermo shrinking sleeves solder all the joints cover th...

Страница 9: ...E manually lights up pixels one by one automatically lights up pixels one by one vary the scrolling s speed MODE MODE saves settings If the test confirmed the correct operation in order to close the p...

Страница 10: ...ev 1 00 page 10 of 12 551073 M4 X 12 screws MAX SCREWS 4 mm MAX SCREWS 4 mm 44 mm MAX SCREWS 4 mm 44 mm 44 mm Installation directions Installation on a surface Installation on a surface by using optio...

Страница 11: ...AL4700 Graph i Dot Rev 1 00 page 11 of 12 551073 28 mm M4 X 12 screws Installation on a rope by using optional accessory AL4708 28 mm...

Страница 12: ...AL4700 Graph i Dot Rev 1 00 page 12 of 12 551073...