background image

SCHEDULED MAINTENANCE 

DESCRIPTION 

FREQUENCY 

ENTRUSTED 

OPERATION 

Photocells cleaning 

Monthly 

Operator 

Clean with damp cloth 

Control of gate hinges and supports, balancing of 
the gate 

Annual 

Operator 

Check the status of welds and corrosion. Unhook 
the engine and check the balancing and the 
eventual points of friction. 

Controlling the sensitivity of electronic friction 
(torque adjustment) of the control board. 

Semiannual 

Technician 

Check the adjustment of the couple as described 
in EN 12453 - EN 12445 

Monitoring current dispersion 

Annual 

Technician 

 Verify that the dispersion of current is less than 
7.5 A 

Control of signals 

Semiannual 

Operator 

Verify that the safety warning signage is 
complete and intact 

EMERGENCY MANOEUVRE 

For the manual door locking and unlocking act with the supplied key on the screw C (See fig 1-6).  
1 - Remove the protection cap 
2 - insert the key into the seat allocation as in Figure 1  
3 - Turn the key in the sense of the arrow to the top of the gearmotor to unlock and in the opposite block 

SPARE PARTS 

 

ANTICLOCKWISE: 

 

CLOCKWISE: 

FIG 6 

12-24Vdc

110-220Vac