SCHEDULED MAINTENANCE
DESCRIPTION
FREQUENCY
ENTRUSTED
OPERATION
Photocells cleaning
Monthly
Operator
Clean with damp cloth
Control of gate hinges and supports, balancing of
the gate
Annual
Operator
Check the status of welds and corrosion. Unhook
the engine and check the balancing and the
eventual points of friction.
Controlling the sensitivity of electronic friction
(torque adjustment) of the control board.
Semiannual
Technician
Check the adjustment of the couple as described
in EN 12453 - EN 12445
Monitoring current dispersion
Annual
Technician
Verify that the dispersion of current is less than
7.5 A
Control of signals
Semiannual
Operator
Verify that the safety warning signage is
complete and intact