8.

 

Disconnect the USB  

 

3.0 Remote control standard connected to GRIPONE 2 

 
The remote control standard must be connected to the connector number 4. The red led inform the 

user  about  the  state  of  ECU.  The  lever  switch  permit  to  adjust  (in  real  time)  the  sensitive  of  ECU. 
Moving the lever (from position 1 to 2) the user reduce the sensitive of ECU. The amount of variation is 

equal  to  2  steps  of  parameter  SPINNING.  (Ex.  SPINNING  =  2  and  remote  control  ON  is  equal  to 
SPINNING = 4 and remote control 1).  

Moving the lever to position 1 the red led will flash one time. Moving the lever to position 2 the red led 
will flash two time.  

 
Move the lever switch to position 1 to obtain MORE sensitive. 
Move the lever switch to the right 2 to obtain LESS sensitive. 

 
To use the remote control standard the user must set the parameter REMOTE (in to the ECU) to value 1 (one). Please follow the steps below to 

fix the ECU for remote control standard: 
  

1.

 

Connect the remote control analog to the ECU  

2.

 

Switch on the ECU 

3.

 

Keep pressed the P button until all the red leds stay on 

4.

 

Release the P button. The leds Parameters must be like this:  

 

5.

 

Press one time the P button. The leds Parameters must be like this: 

 

6.

 

Press the V button to set the value of parameter REMOTE to a 1 (one) 

7.

 

Press one time the P button to come back to the standby mode. 

8.

 

Switch off the ECU. 