background image

P200E Shuttle & RAPS200E 

Airpot/Shuttle Brewer Series

Operation and Instruction Manual

Installation

WARNING:  ELECTRIC SHOCK HAZARD!

INSTALLATION OF THIS APPLIANCE SHOULD BE PERFORMED BY
QUALIFIED SERVICE PERSONNEL ONLY.  IMPROPER
INSTALLATION COULD RESULT IN ELECTROCUTION.

See rough-in drawings in this manual for dimensions and locations of
electric and water input.  

Set-Up/Position

1)

Remove the brewer from the packing material and attach its legs.

2)

Position the brewer on a strong, stable table or counter.  Check 
the level front to back and side to side.  Adjust the legs to the 
correct level.

IMPORTANT:

THE PERSON INSTALLING THIS APPLIANCE IS RESPONSIBLE  
FOR ENSURING THAT ELECTRIC AND WATER CONNECTIONS 
MEET THE REQUIREMENTS OF THE  NATIONAL ELECTRIC 
CODE,  NATIONAL PLUMBING CODE, AND ANY LOCAL
ORDINANCES.

Water Hook-up

1)  Water inlet (supply) fitting is located at rear of unit.

2)  Use 1/4" copper or flexible water line to prevent strain.  Do not use low temperature plastic tubing. The connection 

is 1/4" flare.

3)  Water line pressure must be from 30 to 70 psi.

4)  Hot (up to 160F) or cold water may be used.  Hot water offers faster recovery between brews, (Use cold water only

if in-line water filters are implemented before the brewer).

5)  Install a shut-off valve near the brewer.

6)  Installing a filtering system can improve the taste of brewed coffee and extend the life of the brewer.  If your water 

has high calcium (lime), chlorine, or iron content, this is especially important. The filter should be the lime inhibiting 
type if cold water is used.  Contact our Customer Service Department to select the filter for your conditions.

© Grindmaster Corporation, 1996
Printed in the U.S.A.

1004 FORM # AM-308-06

Part # A090-085

Prior authorization must be obtained from
Grindmaster for all warranty claims.

Table of Contents

Installation and Start-up  ......................................1-2

Operation

............................................................3

Adjustments ..........................................................4-5

Cleaning

..........................................................5-6

Service

............................................................7

Troubleshooting

Filling Problems .................................... 8

Heating Problems ................................. 9

Brewing Problems ................................ 10

Exploded View for P200-E ....................................11

Exploded View for P200 (G version)......................12

Exploded View for RAPS200-E..............................13

Exploded View for RAPS200 (G version) ..............14

Rough-In Drawing for P200-E................................15

Rough-In Drawing for RAPS200-E ........................16

Wiring Diagram for P200E/RAPS200-E ..........17

Grindmaster Corporation™

4003 Collins Lane
Louisville, KY 40245 USA
(502) 425-4776     (800) 695-4500
(800) 568-5715 (Technical Service Only)
FAX (502) 425-4664
www.grindmaster.com

!

Содержание P200E

Страница 1: ... water may be used Hot water offers faster recovery between brews Use cold water only if in line water filters are implemented before the brewer 5 Install a shut off valve near the brewer 6 Installing a filtering system can improve the taste of brewed coffee and extend the life of the brewer If your water has high calcium lime chlorine or iron content this is especially important The filter should...

Страница 2: ......

Страница 3: ...OPERLY GROUNDED Start up Connect water line and turn water valve on Check for leaks Plug in power cord supplied to 120 15 Amp 20 Amp for some models see rating plate on unit wall outlet Once the brewer is full of water it will take 15 to 35 minutes to heat The READY LAMP will light when water has reached the set temperature After READY LAMP is lit portion volume may now be checked Insert the brew ...

Страница 4: ... and grind Coffee brewing experts recommend between 6 5 and 8 ounces of coffee per gallon of water for most applications A full Shuttle is 1 5 gallons 4 Slide the basket into the brewer making sure the spout lines up with the top of the Shuttle or Airpot 5 Check that the correct batch size is selected Check the READY light If lit press START 6 Brew time is about 5 minutes for Shuttles and 4 minute...

Страница 5: ...top cover There will always be a small variation 5 in level from batch to batch Before making the timer adjustment do the following 1 Brew a batch of water to determine where the level falls Using a stop watch determine the current brew time Measure the volume of water 2 To determine the desired time setting use the following formula desired brew volume desired brew time _________________ X curren...

Страница 6: ...erature 5 Reinstall top cover with screw then plug unit in return to use Figure B P200 RAPS200 Brewers Cleaning WARNING BURN HAZARD HOT LIQUIDS AND SURFACES ARE PRESENT IN THIS EQUIPMENT TO AVOID BURNS USE CAUTION WHEN CLEANING RINSE HOT PARTS WITH COLD WATER BEFORE CLEANING USE GLOVES OR A HEAVY CLOTH WHEN REMOVING HOT PARTS FROM BREWER After Each Brew 1 Dispose of grounds and rinse brew basket 2...

Страница 7: ...he liner interior with a plastic bristle brush 4 Remove the knurled nut at the top of the gauge glass and clean the glass with a small bottle brush 5 Pour out the contents of the Shuttle 6 Remove the handle assembly of the Shuttle faucet by unscrewing the plastic bonnet 7 Gently wash the faucet seat cup with a soft cloth and warm soapy water 8 Wash the faucet shank with a bottle brush 9 Clean the ...

Страница 8: ... Place tube over drain and release clamp To Remove The Heater 1 Disconnect power and remove top cover of brewer 2 Disconnect wire leads to heater 3 Remove tank cover by loosening retaining nuts Remove heater from cover 4 Replace heater with sealing washers in same configuration When tightening nuts hold element so it does not twist 5 Replace tank cover 6 Replace heater wires Be sure all electrical...

Страница 9: ...l Jumper from C terminal to metal body stops fill Check connections Jumper from HI to C or metal enclosure does not stop fill Remove electrode assembly and clean both probes If this does not work replace assembly Make secure connection of C to metal body Connect black lead for valve to FILL on level control Replace level control Nothing operates Crack water inlet fitting Water pressure before stra...

Страница 10: ... The heating system consists of the following components Thermostat located on the tank or on the front of top control panel under top cover Heating Element located on top of tank under top cover Recovery time is very long Heater faulty See above See above P200 RAPS200 Brewers If you still need help call our Service Department at 800 568 5715 press 2 Monday through Friday 8 a m 6 p m EST or an aut...

Страница 11: ...b water line so its pressure is not influenced by other appliances Brew will not start Tripped circuit breaker Brew valve faulty Stop switch faulty Start switch faulty Timer faulty Check to see if circuit breaker tripped or popped out Check 120V across brew valve Check for continuity across stop switch when not pressed Check 120V between S S and N on timer when start is pressed Check 120V between ...

Страница 12: ...Page 11 P200 RAPS200 Brewers Exploded View for the P200 E ITEM DESCRIPTION PART ...

Страница 13: ...Page 12 P200 RAPS200 Brewers Exploded View for the P200 G version only ITEM DESCRIPTION PART ...

Страница 14: ...Page 13 P200 RAPS200 Brewers Exploded View for the RAPS200 E ITEM DESCRIPTION PART ...

Страница 15: ...Page 14 P200 RAPS200 Brewers Exploded View for the RAPS200 G version only ITEM DESCRIPTION PART ...

Страница 16: ...Page 15 P200 RAPS200 Brewers Rough In Drawing for the P200 E ...

Страница 17: ...Page 16 P200 RAPS200 Brewers Rough In Drawing for the RAPS200 E ...

Страница 18: ...Page 17 P200 RAPS200 Brewers Wiring Diagram for P200 E RAPS200 E ...

Страница 19: ......

Страница 20: ...ties are null and void if muriatic or any other form of hydrochloric acid is used for cleaning or deliming our equipment NOTE THIS WARRANTY SUPERSEDES ANY OTHER WARRANTY ALL OTHER WARRANTIES EXPRESSED OR IMPLIED INCLUDING THE WARRANTIES OR MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE OR USE ARE HEREBY EXCLUDED AND DISCLAIMED HOW TO OBTAIN WARRANTY SERVICES Call Grindmaster Service Departme...

Отзывы: