Grindex MINEX Скачать руководство пользователя страница 2

Installation, care and maintenance 

Minex

2

Guarantee

Grindex undertakes to remedy faults in products 

sold by Grindex provided:

— that the fault is due to defects in design, ma-

terials or workmanship;

— that the fault is reported to Grindex or Grin-

dex’s rep resentative during the guarantee 

period;

— that the product is used only under condi-

tions described in the care and maintenance 

instruc tions and in applications for which it is 

intended;

— that the monitoring equipment incorporated in 

the product is correctly connected;

— that all service and repair work is done by a 

workshop authorized by Grindex;

— that genuine Grindex parts are used.

Hence, the guarantee does not cover faults 

caused by defi cient maintenance, improper 

installation, in correctly executed repair work or 

normal wear and tear.

Grindex assumes no liability for either bodily 

injuries, material damages or economic losses 

beyond what is stated above.

Grindex guarantees that a spare parts stock will 

be kept for 10 years after the manufacture of 

this product has been discontinued.

The manufacturer reserves the right to alter 

perfor mance, specifi cation or design without 

notice.

Guarantee  ___________________2
Data plate interpretation ________2
Safety precautions _____________3
Product description  ____________4

Applications  _____________________ 4
Motor data   ______________________ 4
Dimensions and weights ____________ 5

Performance curves   _________ 6-7
Transportation and storage ______8
Installation  __________________8
Electrical connections  _______ 9-12

Operation   __________________13
Care and maintenance   ________14

Safety precautions  _______________ 14
Inspection   _____________________ 14
Recommended inspections  _______ 15-16
Changing the oil  _________________ 17
Removing the impeller  __________ 18-19
Installning the impeller and setting
clearance   ____________________ 19-20

Tools  ______________________21
Service log   _________________21

Contents

Data plate interpretation

F

E

G

C

K

A

J

S

H

D

R

B

M

L

N

O

Q

P

I

Data plate interpretation 

 

A  Pump model
B  Serial No.
C  Rated voltage
D  Maximum height
E  Direction of impeller rotation
F  Direction of start reaction
G  Rated current
H  Maximum capacity
I  Degree of protection
J  Maximum submersion depth
K  Pump type No.
L  Frequency
M  Phases, type of current
N  Rated shaft power
O  Thermal class
P  Locked rotor code letter
Q  Country of origin
R  Maximum power consumption
S

  Weight

Содержание MINEX

Страница 1: ...Installation care and maintenance MINEX www grindex com No 89 73 73 Revision 02 2008 04 ...

Страница 2: ... specification or design without notice Guarantee ___________________2 Data plate interpretation ________2 Safety precautions_____________3 Product description ____________4 Applications _____________________ 4 Motor data ______________________ 4 Dimensions and weights ____________ 5 Performance curves _________ 6 7 Transportation and storage ______8 Installation __________________8 Electrical con...

Страница 3: ...lations of your local electricity supply company Unilateral modification and spare parts manufacturing Modifications or changes to the unit installation should only be carried out after consulting with Grindex Original spare parts and accessories authorized by the manufacturer are essential for compli ance The use of other parts can invalidate any claims for warranty or compensation Recycling Loca...

Страница 4: ...nt A 220 D 4 8 20 230 D 4 7 21 380 Y 2 8 12 400 Y 2 7 12 415 Y 2 7 13 500 Y 2 1 9 550 Y 2 1 10 3 50 Hz 2740 r min Rated output 1 2 kW 1 6 hp Max cons 1 6 kW 2 1 hp Vol tage V Rated cur rent A Star ting cur rent A 220 D 5 4 29 230 Y 5 2 27 380 Y 3 1 17 460 Yser 2 6 14 480 Yser 2 6 14 575 Y 1 8 9 9 600 Y 2 0 10 3 60 Hz 3365 r min Rated output 1 4 kW 1 9 hp Max cons 1 8 kW 2 4 hp Motor data Motor typ...

Страница 5: ...5 Installation care and maintenance Minex Dimensions and weights ...

Страница 6: ... 3 phase 50 Hz 10 20 30 50 40 60 0 2 0 1 8 1 P hp kW Head feet m Capacity l s usgpm 30 60 90 120 150 180 1 6 1 4 0 2 4 6 8 10 0 2 4 6 8 10 12 14 16 18 1 0 1 2 1 4 10 20 30 50 40 60 0 2 0 1 8 1 P hp kW Head feet m Capacity l s usgpm 30 60 90 120 150 180 1 6 1 4 0 2 4 6 8 10 0 2 4 6 8 10 12 14 16 18 1 0 1 2 1 4 0 85kW 0 85kW 1 3kW 1 3kW ...

Страница 7: ... 1 8 1 P hp kW Head feet m Capacity l s usgpm 30 60 90 120 150 180 1 6 1 4 0 2 4 6 8 10 0 2 4 6 8 10 12 14 16 18 1 0 1 2 1 4 10 20 30 50 40 60 0 2 0 1 8 1 P hp kW Head feet m Capacity l s usgpm 30 60 90 120 150 180 1 6 1 4 0 2 4 6 8 10 0 2 4 6 8 10 12 14 16 18 1 0 1 2 1 4 1 6 12 20 1 3kW 1 0kW 1 3kW 1 0kW ...

Страница 8: ...e starting to work on the pump or moving the pump make sure that the pump is isolated from the power sup ply and cannot be energized This applies to the control cir cuit as well The pump is frostproof as long as it is operating or is immersed in the liquid If the pump is taken up when the temperature is below freezing the impeller may freeze The pump shall be operated for a short period after bein...

Страница 9: ...d lead is cor rectly connected by testing it NOTE Make sure that the monitoring equipment incorporated in the product is correctly connected and in use WARNING If the pump is equipped with automatic level control or con tactor unit there is a risk of sudden restart WARNING Bear in mind the risk of elec trical shock if the electrical connections are not correctly carried out or if there is fault or...

Страница 10: ... con struction sites and farms the earthed grounded socket must have an addi tional earth ground fault protection device GFI connected WARNING When pumping near a lake jetties beaches ponds fountains etc a safety dis tance of at least 20 m 65 ft between the person and the pump is applicable The pump must never be placed directly into a swim ming pool If used in connection with swimming pools spe c...

Страница 11: ...11 Installation care and maintenance Minex 50 60 Hz 3 SUBCAB SUBCAB AWG Screened cable with contactor unit Y or D with or without transformer operation ...

Страница 12: ...oved only for 250 V and below For other voltages when CSA approval is required a transformer is used to reduce the voltage over the thermal contacts As a consequence the transformer has to be disconnected when the connection is changed from 440 460 V Yser to 220 240 V Y or to 230 V single phase If the change is done from 220 240 V Y or 230 V single phase to 440 460 V Yser the transformer has to be...

Страница 13: ...pped with SMART ROTASENSE rotation control Note the following at start Connect the pump to power If the pump fails to start and the fuses are correct shift two phases in the CEE plug or turn the knob on phase shifter to start the pump NOTE Do not reverse phase sequence while pump motor is running Doing so may cause temporary incorrect rotation resulting in damage to motor electronics and rotating ...

Страница 14: ...ave a major overhaul in a service shop once a year This requires special tools and should be done by an authorized service shop When the pump is new or when the seals have been replaced inspection is recommended after one week of operation WARNING Before starting to work on the pump or moving the pump make sure that the pump is isolated from the power sup ply and cannot be energized This applies t...

Страница 15: ...ng on the inspection screw or its sealing surface is dam aged that an O ring is damaged that the cable entry is leaking If there is oil in the inspections chamber the cause may be that the inner mechanical seal is damaged Contact a Grindex serv ice shop Replace or fix worn and damaged parts Make sure that all screws bolts and nuts are tight Replace worn parts if they impair function A check of the...

Страница 16: ...w position on the cable replace the seal sleeve check that the seal sleeve and the washers conform to the outside diameter of the cables Replace the cable if the outer jacket is damaged Make sure that the cable do not have any sharp bends and are not pinched If faulty contact an electrician Repair faults and notify supervisor of any faults or defects Contact a Grindex service shop Cables Starter e...

Страница 17: ...ll up with new oil A paraffin oil with viscosity close to ISO VG32 is recommended The pump is delivered from fac tory with this type of oil In applications where poisonous properties are of less concern a mineral oil with viscosity up to ISO VG32 can be used Always replace the O rings on the oil screws Put the screws back and tighten them Changing the oil Lift the pump horizontally on relief table...

Страница 18: ...e impeller with a screw driver or similar L min 200 mm 7 9 inch see fig to prevent rotation of the impeller Loosen and remove the impeller screw and washer WARNING Worn impellers often have very sharp edges Use protec tive gloves Remove the strainer Remove the diffuser part ...

Страница 19: ...etting clearance Make sure that the end of the shaft is clean and free from burrs Polish off any flaws with fine emery cloth Grease end of shaft conical sleeve and the threads of the adjustment screw The proper lubrication is grease for bearings e g Exxon Mobile Unirex N3 or equivalent NOTE Remove surplus grease from conical and cy lindrical surfaces of the shaft and the sleeve thoroughly Align th...

Страница 20: ...ck that the impeller rotates freely When changing an impeller or after service we recommend that the screw is first tightened to the prescribed torque and then turned an ad ditional 1 8 45 of a revolution The screw will be loaded to its yield point and the load capacity of the joint will be higher Using a 8 mm hexagon bit adaptor allen socket with a 100 mm 4 extension turn the adjust ment screw cl...

Страница 21: ...al tools exclusively for this pump type without which the servicing of the pump will be difficult and the pump can be very easily damaged Service log Most recent service date Pump No Hours of operation Remarks Sign Part No Denomination Remarks 51 084 00 Spring puller Spring removal 410 164 Puller Main bearing 410 165 Puller Support bearing 410 166 Bearing mounting set Bearings Tools ...

Страница 22: ...Installation care and maintenance Minex 22 Service log Most recent service date Pump No Hours of operation Remarks Sign ...

Страница 23: ...23 Installation care and maintenance Minex Service log Most recent service date Pump No Hours of operation Remarks Sign ...

Страница 24: ...Grindex AB Hantverkarvägen 24 Box 538 136 25 Haninge Sweden Tel 46 8 606 66 00 Fax 46 8 745 53 28 marketing grindex com www grindex com 897373 EN 2008 04 ...

Отзывы: