grifo
®
ITALIAN TECHNOLOGY
Page 6
Tele Web Controller Rel. 5.00
INTERNET INTERFACE
Internet interface is module Micro Web Server, a real HTTP server based on the resources of a
microcontroller and capable to connect to any local network or router through the Ethernet interface.
This module features several on board resources, for a complete description please refer to the Micro
Web Server.
In detail, RS 232 interface of Micro Web Server is used to communicate to GPC
®
control card and
to reach the resources of other peripheral modules.
OUTPUT SECTION OF ZBR
This section can feature 4, 8 ,16 or 32 latched output signals, according to the model ordered.
Each output signal is visualized through a LED and controls a 3 A relay, normally open, provided
with MOV 24 Vac noise suppressor.
These signals can be completely driven by the icons on the commands Web page, which also show
the outputs status using a different color.
Clicking on the icon of a signal complements its status.
OUTPUT SECTION OF ZBT
This section can feature 4, 8 ,16 or 32 latched output signals, according to the model ordered.
Each output signal is galvanically isolated, visualized through a LED and controls a not continuous
4 A Open Collector 45 Vdc Darlington Transistor, provided with suppression diode.
These signals can be completely driven by the icons on the commands Web page, which also show
the outputs status using a different color.
Clicking on the icon of a signal complements its status.
INPUT SECTION OF ZBT AND ZBR
This section can feature 8, 16, 24 or 32 input signals, according to the model ordered.
Each input signal is galvanically isolated by type NPN optocouplers and visualized through a LED.
Above mentioned optocouplers must be supplied through a tVopto generated by on board
supply section.
Different status of each input is indicated using different colors.
POWER SUPPLY SECTION
Tele-Web features an efficent power supply circuitery that can accept a wide range of input tensions
and generates the re5 Vdc voltage to supply output and logic sections in every load condition
and also generates the +Vopto voltage required by the Input optocouplers.
Please refer to ZBx manual for further information.
Содержание Tele Web
Страница 2: ......
Страница 13: ...ITALIAN TECHNOLOGY grifo Page 7 Tele Web Controller Rel 5 00 FIGURE 2 PHOTO OF TELE WEB...
Страница 19: ...ITALIAN TECHNOLOGY grifo Page 13 Tele Web Controller Rel 5 00 FIGURE 5 MICRO WEB SERVER COMPLETE DELIVERY...
Страница 27: ...ITALIAN TECHNOLOGY grifo Page 21 Tele Web Controller Rel 5 00 FIGURE 12 CHANGE SIGNALS NAMES...
Страница 34: ...grifo ITALIAN TECHNOLOGY Page A 4 GMB HR168 GMM AC0 Rel 5 00...