Please read and understand instructions before attempting installation
Grifco MinEB Users Manual
MinEB installation and users manual
Rev: 602140
Contents:
Introduction
Page 1
MinEB layout
Installation
Installing the MinEB
Page 2
Trigger input
Relay output
Installation Examples
Dock Leveller
Alarm system emergency close
Page 3
Warranty / Guarantee
Page 4
Grifco Advanced Users
QUICK START GUIDE
INSTALLING
• Remove power
• Remove lid
• Install MinEB into EXPANSION socket on MCB
• Adjust dipswitches
• Replace lid and resume power
DIPSWITCHES
Trigger Input Functions:
Relay Settings:
For a more detailed explanation on installation, setup,
and operation please read booklet
Dipswitch 1
Dipswitch 8
Trigger Action
OFF
OFF
Operator closes to closed limit
ON
OFF
Operator opens to open limit
OFF
ON
Operator is isolated if 24V is applied
to the trigger
ON
ON
Operator is isolated when no voltage
is applied.
SW2 SW3 SW4 SW5 SW6 SW7
Relay Behaviour
ON
OFF
OFF
OFF
OFF
OFF
Closed position
OFF
ON
OFF
OFF
OFF
OFF
Opened more then 50%
OFF
OFF
ON
OFF
OFF
OFF
When not closed
OFF
OFF
OFF
ON
OFF
OFF
While running
OFF
OFF
OFF
OFF
ON
OFF
While r1 min
OFF
OFF
OFF
OFF
OFF
ON
While running 1Hz
Introduction
Congratulations on your purchase of the Grifco MinEB. The MinEB is a low cost logic upgrade designed to easily provide
extra features to the Maestro Operator. Its features include a relay output with adjustable behaviours, and an auxiliary
OPEN\CLOSE trigger input.
It is the perfect solution for connecting a simple peripheral device to the Maestro operator, such as a dock leveller, alarm
switchboard, hazard lights, and many more.