Black and white adjustment
Generally, users do not need perform the black and white calibration in the application of CA10. If
necessary, it shall be performed as follows.
1)
Remove the left and right baffles;
2)
Place a piece of black and white calibration paper level in the input slot (required to use the
special calibration paper provided by GRG)
3)
Click the “Maintain CMD” and “Black/White calibrate” to feed the calibration paper and
complete the black calibration;
4)
After finished black calibration, it will automatically pop up a window to remind you
whether to continue the white calibration or not, put the calibration paper in the input slot again
and click “yes” to complete the white calibration;