background image

 

 

 

 

CA-10 

Fast Deposit Module 

User Manual 

 

 

No.: 

Version:  V1.0 

Issued on: September 2017 

Содержание CA-10

Страница 1: ...CA 10 Fast Deposit Module User Manual No Version V1 0 Issued on September 2017 ...

Страница 2: ... History No and name Version Date Revision description Personnel involved Fast Deposit Module CA 10 User Manual V1 0 2017 09 Created Prepared Dai Xiaowei Huang Changyan Approved by Wang Yunlong Zhang Enfu Fast Deposit Module CA 10 User Manual V1 1 2018 03 Match with new Toolplus Prepared Liu Peng Approved Zhang Enfu ...

Страница 3: ...pace requirements 6 Chapter 4 Method to Debug and Maintain CA10 with Toolplus 8 1 Install Toolplus 8 2 Connecting CA10 to PC 8 3 Run the Toolplus 12 4 Upgrade main control board 13 5 Upgrade DSP 16 6 Upgrade FPGA 18 7 View version 20 8 Set currency type 20 9 Set work model 21 10 Deposit process 22 11 Get the note information 26 12 Compensation image collection 27 13 Reject image collection 28 14 T...

Страница 4: ...ition As shown in Figure 1 1 the CA 10 module is divided into 10 parts depending on their functions 1 Input slot 2 Note validator 3 Thickness assembly 4 Lower transport 5 Diverter 6 Reject slot 7 Escrow slot 8 External shutter 9 Output slot 10 Internal shutter 11 Pressure plate 12 Connection port 1 2 3 12 6 7 8 9 5 4 10 11 Figure 1 1 ...

Страница 5: ...ed envelope Max length 178 mm width 90 mm thickness 15 mm Slot quantity 1 input slot 1 output slot and 1 escrow slot Overall dimensions Length 423 mm Width 3 40 mm Height 394 mm Power supply environm ent 100 240 VAC 50 60Hz Weight Net weight 19 kg Communi cation interface LAN 3 Note processing procedure 3 1 Loading procedure As shown by the red path in Figure 1 2 the notes fed into the note valida...

Страница 6: ...t the external shutter opens automatically and then it is required to take out the notes from the escrow slot manually and deposit again Figure 1 3 3 3 Deposit process As shown in Figure 1 4 the pressure plate presses forward the notes and the sensor performs the second detection If notes are stacked normally in the escrow slot the delivery roller rotates anticlockwise and the notes are delivered ...

Страница 7: ...Fast Deposit Module CA10 User Manual Confidential material of GRG No disclosure to unauthorized Party 4 35 Figure 1 4 ...

Страница 8: ...mensions are shown in Figure 2 1 Figure 2 1 2 Wiring As shown in Figure 2 2 the external interfaces of CA 10 module are divided into power interface and communication interface in which the power supply is 100 240VAC and the communication is realized by RJ45 cable which is used to control data interaction and transmission Figure 2 2 Power interface Power switch RJ45 cable interface ...

Страница 9: ...rty 6 35 Chapter 3 Installation 1 Installation dimensions Refer to Figure 3 1 for the dimensions of mounting holes and fix the bottom of the CA10 Figure 3 1 2 Maintenance space requirements To facilitate the overall cleaning and maintenance it is necessary to reserve enough space in Output slot size ...

Страница 10: ...Module CA10 User Manual Confidential material of GRG No disclosure to unauthorized Party 7 35 advance As shown in Figure 3 2 turn up the upper transport of CA10 to clean the space required for maintenance Figure 3 2 ...

Страница 11: ...ish Double click to run the test tool CA10_ToolPlus note for Windows XP operating system it is required to remove the manifest file under the installation directory to run the tool normally after installation 2 Connecting CA10 to PC 2 1 Connecting to PC with cable The IP address of CA10 is set by default upon the delivery from factory IP address 192 168 1 12 Port 7500 Connect CA10 to PC with the R...

Страница 12: ... network first obtain the Local Connection IP address for PC in local area network 2 Using the method in 2 1 mentioned above to connect CA10 with PC click System CMD and Set IP write the same IP address as that of Local Connection for PC in the pop up setting box but the number 12 cannot be same for other PCs in the local area network click OK to display the successful interface and click OK again...

Страница 13: ...Fast Deposit Module CA10 User Manual Confidential material of GRG No disclosure to unauthorized Party 10 35 ...

Страница 14: ...e CA10_ToolPlus again write the same IP address and port in step 2 and click the Connect button for a successful connection 2 3 Recovery of default IP address To recover the default IP address of CA 10 upon the delivery from factory turn pin 2 of the dial switch to OFF position on the main control board and turn it to the ON position after hearing the beep three times to finish the reset of IP add...

Страница 15: ... CA10 after hearing three beep sound then click the Connect button CA10 will connect with PC automatically If there is no the beep click the Connect button about 15 seconds later after powering on CA10 display ModuleSN BOC17 GRG CA1000000001 in the Message area for a successful connection Otherwise display the error information in the ...

Страница 16: ... below after the error information is excluded check the sensor states which should be same as the area of Sensor State in the following figure to show the sensors working normally Click the Init button to initialize CA10 successfully and display Success in the Massage area 4 Upgrade main control board 4 1 Online download Click the Upgrade button ...

Страница 17: ...package of the main control board and then click the Open button Then it will pop up confirm interface click yes to automatically finish firmware update until the appearance of Upgrade success click yes it will automatically re connect with CA 10 but if the connection is failed please click the Connect button and reconnect to PC ...

Страница 18: ...en CA10 is unavailable for the lost of the main control firmware Power off CA10 device copy the main control upgrade file YT2 480 0618CX_ S to the root directory of the USB flash disk and insert the disk into the U slot on NV board as shown in the figure below Turn pin 1 of the dial switch on the main control board to OFF position see the following figure ...

Страница 19: ... flash disk and turn pin 1 of the dial switch on the main control board to ON position Restart CA10 and connect to PC view the version and contrast the main control version using the method of step 7 below If the version is same as the upgrade file version it indicates that the upgrade is successful If failed please operate as above again 5 Upgrade DSP Click the Upgrade button Pitch on the upgrade...

Страница 20: ...unauthorized Party 17 35 Then it will pop up confirm interface click yes to automatically finish DSP update until the appearance of Upgrade success click yes it will automatically re connect with CA 10 but if the connection is failed please click the Connect button and reconnect to PC ...

Страница 21: ...posit Module CA10 User Manual Confidential material of GRG No disclosure to unauthorized Party 18 35 6 Upgrade FPGA Click the Upgrade button Pitch on the upgrade package of FPGA and then click the Open button ...

Страница 22: ...nauthorized Party 19 35 Then it will pop up confirm interface click yes to automatically finish FPGA update until the appearance of Upgrade success click yes it will automatically re connect with CA 10 but if the connection is failed please click the Connect button and reconnect to PC ...

Страница 23: ...sure to unauthorized Party 20 35 7 View version After the connection with PC click System CMD and Get Version to view correctness of the upgraded version in the Message area 8 Set currency type Click System CMD and Get Currency to view currency type supported by DSP currently ...

Страница 24: ...de Select and Denom Type to select work modes as follows Authentic It is mainly used to authenticate notes and identify other properties of the notes including currency and denomination Counting Only count the number of the media including notes receipts and securities Sigal Set the denomination of note according to the first acceptable note Config Set the denomination accepted or rejected in the ...

Страница 25: ...osit process 1 Click Cotrol CMD and click the buttons in the red box of the figure below to check whether each actuator is normal or to debug Start motor To start motor Stop motor To stop motor Open OGate To open the external shutter Close OGate To close the external shutter Open IGate To open the internal shutter ...

Страница 26: ...ear To clear the transport Init To initialize the process Click More to check more components Diverter up The diverter is in upper position Diverter up The diverter is in lower position Clutch To clutch Brake To brake Stop Brake Clutch To brake clutch LED Open to open the LED light in the escrow slot LED Close To close the LED light in the escrow slot ...

Страница 27: ...Fast Deposit Module CA10 User Manual Confidential material of GRG No disclosure to unauthorized Party 24 35 ...

Страница 28: ...ith a pressure plate and move the internal shutter to the specified position Click Confirm Deposit to deliver the notes to the escrow slot or the output slot note before he Pre Deposit and after the Confirm Deposit the system will report error with the detection of notes stacked abnormally in the escrow slot cancel the deposit automatically and open the external shutter automatically to take out t...

Страница 29: ... counting click Get Note Info to get the identification information of the current notes which generates and stores a Excel csv file with a suffix of HM corresponding to the time the directory where the files was stored will show in the window The Excel can be opened to view the reason of rejecting notes please provid it to GRG engineers if necessary ...

Страница 30: ...feed the notes Click Image collect to enable the system to collect compensation images of these notes automatically and to store the collected images in the corresponding CLT folder in the folder named CA10_image under the root directory of CA10_ToolPlus Each collection will generate a folder Due to the large image files and long collection time it is recommended to collect less than 20 images per...

Страница 31: ...than 20 images Generate automatically an image file after collection and store it in the corresponding folder REJ in the folder named CA10_image under the root directory of CA10_ToolPlus Each collection will generate a folder Click Clear Reject Image to clear all stored reject images in the current system Reject images are only collected to meet the need of GRG engineers 14 Thickness calibration R...

Страница 32: ...right baffles 2 Place a piece of black and white calibration paper level in the input slot required to use the special calibration paper provided by GRG 3 Click the Maintain CMD and Black White calibrate to feed the calibration paper and complete the black calibration 4 After finished black calibration it will automatically pop up a window to remind you whether to continue the white calibration or...

Страница 33: ...sclosure to unauthorized Party 30 35 16 Error code query Display an error code when CA10 has a prompt of error click Error Code and input the last 4 characters of the error code to learn more about the error information click OK to get detailed information about the fault ...

Страница 34: ...45 65 and the qualified thickness K value is within 30 50 Click Maintain CMD and click Start get thick to read the thickness zero value and thickness K value in the histogram or in the Message area After read the thickness zero value click Stop get thick to recover the state When there are thickness fault or notes are rejected for thickness problems and the read thickness zero value and thickness ...

Страница 35: ...ack cover plate 2 As shown in the following figure press the buckle with one hand and pull out the baffle with another hand to remove the left and right baffles 3 Place 10 calibration notes or more with a special thickness of 110 μm in the input slot neatly click TIDH and after the calibration notes are fed in check whether the thickness K value displayed in the Message area is within 30 50 Back c...

Страница 36: ...combination screws shown in the following figure with a screwdriver slight adjust the thickness base position around and tighten the screws again Repeat the step 3 until the thickness K value is in the range of 30 50 and repeat the step 3 twice to achieve a successful thickness calibration in which the fluctuation difference of the three thickness K values is less than 5 ...

Страница 37: ... read whether the thickness zero value is in the range of 45 65 if not rotate the potentiometer adjusting screws with a small slotted screwdriver and adjust to the qualified range clockwise is to decrease and anticlockwise is to increase click Stop get thick after this adjustment and reset the back cover plate after the whole thickness adjustment ...

Страница 38: ...n a If the note feeding clearance is too tight easily to observe the conditions that the notes are not loaded smoothly and the counting is not continuous b If the note feeding clearance is too loose with overlapped and consecutive notes easily to observe that the reject bin counts two or more notes at the same time and view the reject reasons including wrong transportation and the note is too thic...

Страница 39: ...rocess and the width between the plates is adjusted to be available for 100 yuan The clearance is too tight Adjust in the opposite direction of too loose above Or refer to the experience adjustment method as follows Insert notes into feeder roller to test the clearance while turning the scale the standard is that notes can not be fed as the rubber wheel groove is upwards the notes can be fed as th...

Страница 40: ...al of GRG No disclosure to unauthorized Party 37 35 Chapter 7 Overall Development Support We provide CA10 to users in a manner of module and we also can provide dynamic development library SDK files of CA10 to facilitate a rapid overall development for users ...