Page 48
AVFM 5.0 Area-Velocity Flow Meter
PZxx FLANGE SENSOR MOUNTING METHODS IN ROUND PIPES
Notes:
1. Use the ¾” NPT “Isolation
Coupling” supplied and hand
tighten only. Do not clamp sensor
body or stem.
2. Do not mount sensor or cover
flange in direct sunlight.
3. Extend sensor cable up to 500 ft
(150 m) with RG62AU coaxial
only and junction box.
4. Standpipe diameter as large as
possible, typical standpipe: 6” /
150 mm diameter, 12” – 16” (300
– 500 mm) height.
Use a Sensor Sunscreen (option PZS) when sensor is installed indirect sunlight.