PROPERTIES

WIRING DIAGRAM

Connect the module according to the diagram above, and then add the Z-Wave  

module to CLU controller. To do this, follow these steps:

1. 

Press the “Link” button located on the CLU module (green LED blinks in 200 ms intervals).

2. 

Press the button located on the added Z-Wave module.

If the module was added correctly, it will be signalled by three blinks of green and red LEDs  
on the CLU. After physically pairing the module with CLU, perform system configuration.  

In order to do so, follow these steps:

1. 

Connect the CLU module using the ETHERNET port to the computer on which  
the GRENTON OBJECT MANAGER configuration program is installed.

2. 

Open a new project or create a new one in GRENTON OBJECT MANAGER program.

3.

  Run the CLU DISCOVERY procedure.

 

4. 

Add found modules to the project.

MODULE INSTALLATION

  enables you to connect four 230 V inputs 

  inputs are fully configurable

  small size – fits into a P60 box under the ancillary equipment 

  each input can carry out up to seven independent functions

  each function can request up to four events simultaneously

  operates with 230 V supply

  communicates with other wireless modules using a mesh network

GRENTON DIGITAL IN Z-Wave

 

INP-038-Z-04

 

WIRELESS DIGITAL INPUT MODULE 

 

FOR FLUSH-MOUNT ASSEMBLY

Wireless digital input module 
for flush-mount assembly 
allows you to connect any 
input with the system.

CONFIGURATION PARAMETERS

CHARACTERISTICS

NAME

DESCRIPTION

Value

Returns input mode as 0 or 1

Inertion

Minimum interval in milliseconds which has to pass between presses of  
a button so that it is interpreted as a new pressing task

HoldDelay

Time in milliseconds after which, when pressing  
and holding a button, the OnHold event occurs

HoldInterval

Cyclical interval in milliseconds after which, when pressing  
and holding a button, the OnHold event occurs

METHODS

NAME

DESCRIPTION

SetInertion

Sets Inertion value

SetHoldDelay

Sets HoldDelay value

SetHoldInterval

Sets HoldInterval value

EVENTS

NAME

DESCRIPTION

TECHNICAL SPECIFICATIONS

OnChange

Occurs when a change in the input state takes place (regardless of the value)

OnSwitchOn

Occurs when the high state is set at input

OnSwitchOff

Occurs when the low state is set at input

OnShortPress

Occurs after pressing the button for 500 - 2000 ms

OnLongPress

Occurs after pressing the button for two seconds

OnHold

Occurs for the first time after HoldDelay time passes  

and then cyclically every HoldInterval Value

OnClick

Occurs after pressing the button for less than 500 ms

AC supply

230 V

average current input

2 mA

max. current input

3 mA

Z-Wave frequency

868 MHz

weight

27 g

dimensions (H/W/D) 

 19/45/36 mm

max. connection wire section

≤ 1.5 mm

2

operating temperature range

O to +40°C

~230 V

L

N

v. 1.1