PROPERTIES
WIRING DIAGRAM
Connect the module according to the diagram above, and then add the Z-Wave
module to CLU controller. To do this, follow these steps:
1.
Press the “Link” button located on the CLU module (green LED blinks in 200 ms intervals).
2.
Press the button located on the added Z-Wave module.
If the module was added correctly, it will be signalled by three blinks of green and red LEDs
on the CLU. After physically pairing the module with CLU, perform system configuration.
In order to do so, follow these steps:
1.
Connect the CLU module using the ETHERNET port to the computer on which
the GRENTON OBJECT MANAGER configuration program is installed.
2.
Open a new project or create a new one in GRENTON OBJECT MANAGER program.
3.
Run the CLU DISCOVERY procedure.
4.
Add found modules to the project.
MODULE INSTALLATION
•
enables you to connect four 230 V inputs
•
inputs are fully configurable
•
small size – fits into a P60 box under the ancillary equipment
•
each input can carry out up to seven independent functions
•
each function can request up to four events simultaneously
•
operates with 230 V supply
•
communicates with other wireless modules using a mesh network
GRENTON DIGITAL IN Z-Wave
INP-038-Z-04
WIRELESS DIGITAL INPUT MODULE
FOR FLUSH-MOUNT ASSEMBLY
Wireless digital input module
for flush-mount assembly
allows you to connect any
input with the system.
CONFIGURATION PARAMETERS
CHARACTERISTICS
NAME
DESCRIPTION
Value
Returns input mode as 0 or 1
Inertion
Minimum interval in milliseconds which has to pass between presses of
a button so that it is interpreted as a new pressing task
HoldDelay
Time in milliseconds after which, when pressing
and holding a button, the OnHold event occurs
HoldInterval
Cyclical interval in milliseconds after which, when pressing
and holding a button, the OnHold event occurs
METHODS
NAME
DESCRIPTION
SetInertion
Sets Inertion value
SetHoldDelay
Sets HoldDelay value
SetHoldInterval
Sets HoldInterval value
EVENTS
NAME
DESCRIPTION
TECHNICAL SPECIFICATIONS
OnChange
Occurs when a change in the input state takes place (regardless of the value)
OnSwitchOn
Occurs when the high state is set at input
OnSwitchOff
Occurs when the low state is set at input
OnShortPress
Occurs after pressing the button for 500 - 2000 ms
OnLongPress
Occurs after pressing the button for two seconds
OnHold
Occurs for the first time after HoldDelay time passes
and then cyclically every HoldInterval Value
OnClick
Occurs after pressing the button for less than 500 ms
AC supply
230 V
average current input
2 mA
max. current input
3 mA
Z-Wave frequency
868 MHz
weight
27 g
dimensions (H/W/D)
19/45/36 mm
max. connection wire section
≤ 1.5 mm
2
operating temperature range
O to +40°C
~230 V
L
N
v. 1.1