CONTENTS

1

GENERAL ................................................................................................................................................................................. 1

1.1

I

NTENDED USE OF 

GCO 100 ................................................................................................................................................. 1

1.2

S

AFETY INSTRUCTIONS

......................................................................................................................................................... 2

1.3

O

PERATING AND MAINTENANCE ADVICE

: ............................................................................................................................. 2

1.4

D

ISPOSAL INSTRUCTIONS

...................................................................................................................................................... 2

2

OPERATION ............................................................................................................................................................................. 2

2.1

D

ISPLAY ELEMENTS

.............................................................................................................................................................. 2

2.2

P

USHBUTTONS

...................................................................................................................................................................... 2

2.3

C

ONNECTIONS

...................................................................................................................................................................... 3

2.4

G

ENERALS OF 

CO-

MEASURING

............................................................................................................................................. 3

3

ALARM FUNCTIONS.............................................................................................................................................................. 3

4

CONFIGURATION OF THE INSTRUMENT....................................................................................................................... 4

5

ADJUSTMENT.......................................................................................................................................................................... 4

5.1

A

DJUSTMENT 

M

ENUE

........................................................................................................................................................... 5

5.2

A

UTOMATIC ZERO POINT ADJUSTING

..................................................................................................................................... 5

5.3

A

DJUSTMENT WITH REFERENCE GAS

..................................................................................................................................... 5

6

SYSTEM MESSAGES .............................................................................................................................................................. 6

7

THE SERIAL INTERFACE..................................................................................................................................................... 6

8

SPECIFICATION...................................................................................................................................................................... 7

1 General

1.1  Intended use of GCO 100

The GCO 100 is a high value CO-Measuring instrument for the measuring of up to
1000ppm (0,1Vol %)  CO in ambient air.

Via the adjustable alarm function the instrument warns the user optically (display) and
acoustically (integrated horn) when dangerous concentrations are present.

The device must not used as a monitoring device for the personal safety !

The measuring inlet is at the opening of the front plate.

Applications

  control and maintenance of heating systems

  monitoring air quality (signalling exceeding of the maximum allowed working place

concentration MAK)

  detection of CO in the breath of smokers

  detection of CO-toxication of victims of fires (Fire brigades)

  and much more...

Calibration protocol within scope of supply

  

GREISINGER 

electronic GmbH

Содержание GCO 100

Страница 1: ...E 6 8 SPECIFICATION 7 1 General 1 1 Intended use of GCO 100 The GCO 100 is a high value CO Measuring instrument for the measuring of up to 1000ppm 0 1Vol CO in ambient air Via the adjustable alarm fun...

Страница 2: ...result in death or serious injury and material damage 1 3 Operating and maintenance advice If the symbol BAT is displayed at the left side of display the battery is weak measuring can be continued for...

Страница 3: ...he instrument This value is an estimation of the carboxy haemoglobin of blood via the exhaled breath The calculation above 5ppm is done according to M J Jarvis M Belcher C Vessey and D C S Hutchison L...

Страница 4: ...only via display No alarm Alarm boundary not available if alarm function is deactivated AL oFF Alarm boundary in the selected display unit factory setting 10ppm Warning boundary for maximum working pl...

Страница 5: ...gas The instrument can be adjusted to a reference gas by means of a test gas cap and the suitable test gas bottle with gas valve Depending on the application two concentration are offered as standard...

Страница 6: ...nd presentation of measuring data of one device in the ACCESS data base format In case you want to develop your own software we offer a GMH3000 development package including a universally applicable W...

Страница 7: ...ant ABS membrane keyboard transparent panel Front side IP65 integrated pop up clip for table top or suspended use Dimensions 142 x 71 x 26 mm L x W x D Wight approx 155 g Power supply 9V battery type...