background image

H63.0.11.6C-01 

Operating Manual BaleCheck 100 

page 6 of 10 

 

 

_____________________________________________________ 

_____________________________________________________________________________ 

 

5  Principles of the measurements 

5.1  Moisture rating ( WET -  MEDIUM  -  DRY ) 

In addition to the measuring value there is a moisture rating via bar graph:  
Therefore the determination ‘wet’ or ‘dry’ is easy and comfortable for most applications and has no 
longer be deduced from literature and tables.  

However, this rating can only be a first approximate value, because factors like the ap-
plication field of the measured material have to be taken into account for the final rating.  
Experience and knowledge can only be supported by this instrument, not replaced! 

5.2  Moisture 

and water content 

w

 

Either moisture u or water content w is needed according to the application. The BaleCheck 100 is 
supposed to be used the unit moisture u (relating to oven-dry mass). In some cases, like rating of 
combustibles, the water content w may be more suitable.

 

The instrument can be configured to both of the values, please refer to chapter 6. 

Moisture u (relating to oven-dry mass) 

– recommended setting 

The unit is %u (also common: % atro, weight percent) 

mass 

wet 

:  

mass of the sample (= total mass = mass

 water

 

+ mass 

dry

mass 

water 

:   mass of the water contained in the sample 

mass 

dry 

:  

mass of the oven-dried sample after (water has been evaporated) 

Example:  1 kg wet hay that contains 500 g water has a moisture u of 100% 

 Water content w (= moisture relating to wet total mass) 

The unit is % w. 

Example:  1 kg wet hay that contains 500 g water has a water content of 50% 

5.3  Temperature compensation  

The temperature compensation is important for a reliable moisture-measuring.  
There for the device features a manual temperature compensation input. 
According to the selected material characteristic curve the device will use the associated tempera-
ture compensation. 

Temperature selection: 

  

• press shortly 

:  in the left display will appear: 

t.°C

 or 

t.°F

  

  

• set the temperature by pressing 

 or 

 . 

  

• press 

 again to switch back to the measuring display. 

5.4  Auto-Hold function 

Particularly when measuring dry materials, electrostatic charges and other similar noise could dither 
the measuring value. With activated auto-hold function the device will acquire an exact measuring 
value automatically. During that, the device could be put down to avoid noise through discharge of 
the clothing etc.  
After having acquired the measuring value, the display will change to ‘HLD’: The value will be fro-
zen as long as a new measuring is initiated by pressing key 3 (hold). 

 

 

m

oisture u[%] = ( (mass 

wet 

- mass 

dry 

) / mass 

dry

) *100 

or: 

m

oisture u[%] = (mass 

water

 / mass 

dry

) *100

 

 

water content [%] = ( (mass 

wet 

- mass 

dry

) / mass 

wet

) *100 

or: 

water content [%] = (masse 

water

 / mass 

wet

) *100 

 

Содержание BaleCheck 100

Страница 1: ...H63 0 11 6C 01 GREISINGER electronic GmbH as of version 1 0 BaleCheck 100 Operating Manual Hay and straw humidity measuring device WEEE Reg Nr DE 93889386...

Страница 2: ...SSAGES 8 8 RESHIPMENT AND DISPOSAL 9 9 SPECIFICATION 9 1 General Note Read this document carefully and get used to the operation of the device before you use it Keep this document within easy reach ne...

Страница 3: ...guidelines This device has been designed and tested in accordance with the safety regulations for electronic devices However its trouble free operation and reliability cannot be guaranteed unless the...

Страница 4: ...100 Measuring probe GSF 40 9V battery Operating Manual Protection bag ST KR 3 2 Operation and maintenance advice a Battery operation If bAt is shown in the lower display the battery has been used up...

Страница 5: ...uring display and temperature adjustment Key 2 sort Selection of characteristic curve p r t chapter 4 4 Key 3 hold press shortly The measuring current value is frozen HLD is displayed 4 3 Start of ope...

Страница 6: ...mass water mass of the water contained in the sample mass dry mass of the oven dried sample after water has been evaporated Example 1 kg wet hay that contains 500 g water has a moisture u of 100 Wate...

Страница 7: ...o gather fast and comfortably many measurements spread over the bale store deep inside at the floor at critical weathered places in practical use this often is much more valuable than single precision...

Страница 8: ...actory setting u u Measuring value displayed in moisture u w Measuring value displayed in water content w Display unit of temperature input factory setting C Temperature input in C F Temperature input...

Страница 9: ...ment Measuring ranges 0 0 50 w water content 0 0 100 u material moisture Resolution 0 1 over 19 9 1 for u and w Moisture rating 6 stage bar graph display from WET to DRY Accuracy the achievable accura...

Страница 10: ...H63 0 11 6C 01 Operating Manual BaleCheck 100 page 10 of 10 _____________________________________________________ _____________________________________________________________________________...