GREER COMPANY 1918 East Glenwood Place, Santa Ana, CA 92705 Tel: 714) 259-9702 Fax: 714) 259-7626 PN W414107-
MicroGuard
414 System Lattice Boom Cranes Horizontal Display Clyde M4190 Barge Mount OPERATOR'S MANUAL 12/20/01
16 of 21
THE FUNCTIONS OF THE PUSH BUTTONS WHEN IN THE ALARM SCREEN ARE:
♦
♦
♦
♦
VIEW
USED TO ACCESS THE ALARM SCREEN TO VIEW THE CURRENTLY SET ALARMS.
♦
♦
♦
♦
SET
USED TO SET THE ALARM VALUE. THE ALARM VALUE IS DETERMINED BY THE
POSITION OF THE CRANE AT THE TIME THE SET BUTTON IS PRESSED.
♦
♦
♦
♦
CLEAR
USED TO CLEAR A PREVIOUSLY SET ALARM. ALARMS CAN ONLY BE CLEARED
WHEN THE CURSOR IS POINTING TO THE ITEM TO BE CLEARED. USE THE UP/DOWN
ARROWS TO MOVE THE CURSOR TO THE DESIRED ALARM. PRESS CLEAR TO CANCEL
THAT ALARM.
♦
♦
♦
♦
UP/DOWN ARROWS
USED TO MOVE THE CURSOR UP OR DOWN THE SCREEN TO THE
ALARM, WHICH IS TO BE VIEWED, SET OR CLEARED.
♦
♦
♦
♦
SELECT
USED TO RETURN TO THE NORMAL OPERATING SCREEN.
SETTING THE ALARMS
SETTING THE ALARMS
SETTING THE ALARMS
SETTING THE ALARMS
TO SET ALARM POINT POSITION THE CRANE AT THE POINT AT WHICH THE ALARM IS TO
SOUND. WHEN IN THE OPERATOR ALARM SCREEN, PRESS THE SET BUTTON TO SET THE
ALARM. REFER TO THE EXAMPLES BELOW.
EXAMPLE A
TO SET AN ALARM WHENEVER THE BOOM IS BELOW A 30° ANGLE:
1. PRESS
VIEW
TO ACCESS THE ALARM SCREEN. THE CURSOR WILL BE AT MIN ANGLE.
2. MOVE THE BOOM TO A 30
°
ANGLE.
3. PRESS
SET
TO ENTER THE ALARM. THE DISPLAYED VALUE WILL BE THE ALARM SETTING,
WHICH WILL ALTERNATE WITH THE WORD SET.
4. WHEN THE ALARM IS SET, PRESS
SELECT
TO RETURN TO THE WORKING SCREEN.
THE RED LAMP AND THE AUDIBLE ALARM WILL OPERATE WHENEVER THE BOOM
IS BELOW 30°.THE MESSAGE MIN ANGLE WILL APPEAR IN THE INFORMATION AREA
ON THE LEFT DISPLAY.
EXAMPLE B
TO SET AN ALARM WHENEVER THE BOOM IS ABOVE A 60° ANGLE:
1. BOOM TO A 60° ANGLE.
2. PRESS
SET
TO ENTER THE ALARM. THE DISPLAYED VALUE WILL BE THE ALARM SETTING
AND IT WILL ALTERNATE WITH THE WORD SET. PRESS
SELECT
TO RETURN TO THE
WORKING SCREEN. THE RED LAMP AND THE AUDIBLE ALARM WILL OPERATE WHENEVER
THE BOOM IS ABOVE 60 DEGREES. THE MESSAGE MAX ANGLE WILL APPEAR IN THE
INFORMATION AREA ON THE LEFT DISPLAY.