GREER COMPANY 

Crane Systems 

 

 

 

3. 

CHECK ALL THE SENSOR HARDWARE FOR LOOSE CLAMPS, 

FITTINGS, BOLTS OR NUTS, ETC. 

 

ANNUALLY OR EVERY 1000 HOURS OF OPERATION 

1. 

UNDO  THE  CABLE  CONNECTORS  IN  THE  SYSTEM;  INSPECT  AND 

CLEAN  THESE  CONNECTORS.  GENEROUSLY  REPACK  EACH 

CONNECTOR  WITH  DOW  CORNING  #111  SILICON  GREASE  OR  A 

COMPARABLE SUBSTITUTE. 

2. 

IF  USING  AN  EXTENSION  REEL,  CLEAN  THE  REEL 

CABLE AND GENEROUSLY LUBRICATE IT WITH SILICON 

SPRAY. 

Содержание Crane Systems BA 1510

Страница 1: ...GREER COMPANY Crane Systems BA 1510 ANGLE INDICATOR OPERATOR S MANUAL HYDRAULIC LATTICE CRANES...

Страница 2: ...ienced crane operator in safe crane setup and operation involving boom angles This manual provides the operator with instructions for using the BA 1510 System At no time may this System be used as a s...

Страница 3: ...ANUAL HYDRAULIC LATTICE CRANES BA 1510 ANGLE INDICATOR 5 SETTING AN ANGLE LIMIT LIMIT 5 REMOVING AN ANGLE LIMIT 5 THE ALARMS 6 PRE ALARMS 6 ALARMS 6 MOTION CUTS 7 SPECIAL FUNCTIONS 8 FACTORY RECOMMEND...

Страница 4: ...maximum limit Range 9 9 to 99 9 press to set cancel limits yellow and red warning lamps angle of crane boom press to lighten darken display The BA 1510 Angle Indicator meter BA 1510 Operator s Manual...

Страница 5: ...nd boom down movements are available as an additional option if desired Refer to MOTION CUTS page 7 SETTING AN ANGLE LIMIT Position the crane boom at the desired limit Refer to the illustration on the...

Страница 6: ...nds both the red and yellow lamps light up and a warning message appears Motion cuts if installed will activate OPTIONS WHEN AN ALARM ACTIVATES MOVE OUT OF THE ALARM CONDITION PRESS CANCEL ALARM TO SI...

Страница 7: ...ST UP BOOM DOWN AND TELESCOPE OUT BOOM ACTION DURING A TWO BLOCK CONDITION ACTIVATION OF THE MIN ANGLE ALARM HALTS BOOM DOWN UNLESS THE ALARM WAS PURCHASED AS AUDIOVISUAL ALARMS ONLY ACTIVATION OF THE...

Страница 8: ...ABLED WHEN THE RIGGING MODE IS ACTIVE PRESS CANCEL ALARM TO EXIT THE RIGGING MODE NOTE THIS ACTION WILL RESTORE ALARMS AND MOTION CUT FEATURES IF INSTALLED CALIBRATION MODE TO ACCESS THE CALIBRATION M...

Страница 9: ...LLED 2 IF USING AN ANTI TWO BLOCK SYSTEM TEST THE SYSTEM BY CAUTIOUSLY HOISTING THE HOOK S TO ACTUATE THE SWITCH AND ALARM 3 CHECK THE METER FOR ANY VISIBLE MOISTURE AND KEEP IT AS DRY AS POSSIBLE MON...

Страница 10: ...ALLY OR EVERY 1000 HOURS OF OPERATION 1 UNDO THE CABLE CONNECTORS IN THE SYSTEM INSPECT AND CLEAN THESE CONNECTORS GENEROUSLY REPACK EACH CONNECTOR WITH DOW CORNING 111 SILICON GREASE OR A COMPARABLE...

Страница 11: ......

Страница 12: ...12...

Отзывы: