GREENSTAR GSPDPAD46 Скачать руководство пользователя страница 2

 
 

Document Name 

          AVI Installation Instruction 

 

Template Number 

GSPDPAD46 

Document Number 

PDPAD1220002003 

Document Owner 

ESS Department 

Template Rev 

00 

Document Rev 

AA000 

 

 

GreenStar Products, Inc. 

Page 2 of 2 

 

Product Information

 

 

This product is designed to specifically address the phenomenon known as “dirty power” which is typically 
characterized  by  voltage  swells  above  the  rated  luminaire  voltage  or  voltage  sags  below  the  rated 
luminaire voltage.  
This product is a serial device, meaning that it must be installed before the luminaire.  
 

Inspection 

 

 

The packing has been designed to protect the Autonomous Voltage Interrupter (AVI) from damage 
during transit. Inspect AVI for damage before installation. 
 

Wiring

 

 

NOTE: 

Make sure that all electrical connections are in accordance with the National Electrical Code 

(NEC), and any applicable local code requirements.                                           
 
Connect the Supply wires as shown in below diagram: 

 

Important:  

When making electrical connections, make sure that the Pole has a good ground connection. 

Under no circumstances should the ground wire be left disconnected. This will cause the 
product to fail and will not be covered under warranty. 

Make sure that the insulated wires of the product are not crossed/overlapped by the               
un-insulated wires. 

Ensure that wires are not folding or getting pinched at sharp edges. 

Ensure that all the electrical connections made are correct and properly protected from moisture 
accumulation before energizing the circuit. 
 

 

Note:

 

Use connector(s) as per the size of the supply wires for proper supply connections. 

 
 