background image

Greenplate ® M

yles

 

Double 

Extended Top 

Barbecue Bench Electrical Wiring Requirements

Suggested slab size 

3765

 

mm x 286

5

 mm x 100 mm thick.

Base size of M

yles

 barbecue bench 

1772

 mm x 

8

72 

mm OD

130

 mm turn in for fixing of bench to the concrete slab

6

 

x M10 Dyna bolts 50 mm deep (

S

upplied) 

Level bench by adjusting Leveling Feet.

ELECTRICAL WIRING REQUIRMENTS: 

Electrical wiring to waterproof GPO 10 amp to AS3000:2007 standard requires a minimum of 2.5 mm² cabling for each Greenplate Inbench 

barbecue unit, larger for long runs, with each barbecue unit having it’s own 20 amp RCBO C-Curve type A in the mains sub-board. 

“Under No circumstance should more than one barbecue unit be on one power line.  Failure to install correctly will VOID 

the warranty as damage to the electrical equipment will occur.” 

SINGLE GPO POWER POINT WITH 

SEPARATE 10 AMP CIRCUIT FOR 

EACH INBENCH BBQ UNIT TO BE 

INSTALLED 

50

 mm 

CENTRE 

FROM 

BOTTOM FOLD OF THE 

RIGHT 

SIDE 

PANEL ON A GPO SUPPORT POST.

FRONT

S:\Libraries\Documents\Greenplate BBQ Info\Bench Wiring Requirements\

M

yles 

Double

 Extended Top

 

Barbecue Bench Installation Information PID.doc | Updated 14-08-2018

SINGLE GPO POWER POINT WITH 

SEPARATE 10 AMP CIRCUIT FOR 

EACH INBENCH BBQ UNIT TO BE 

INSTALLED 

5

57

 mm 

CENTRE 

FROM 

BOTTOM FOLD OF THE 

RIGHT 

SIDE 

PANEL ON A GPO SUPPORT POST.