Maintenance
Each Operating Day
Before Use:
1.
Inspect dies for defects, such as cracks, gouges or
chips.
2.
Inspect the tool for damage or leaks. If damage is
detected, return the tool to an authorized Greenlee
service center.
High Pressure Hazard:
Do not use fingers or hands to
check for oil leaks. High pressure
oil easily punctures skin causing
serious injury, gangrene or death.
If injured seek medical help immedi-
ately to remove oil.
Do not use solvents or flammable
cleaners to clean tool body. Sol-
vents could ignite causing serious
injury or property damage.
After Use:
1.
Wipe clean and dry all exposed surfaces.
Note: Use a slightly damp cloth and a mild
detergent to clean the cutter body. Solvents
can damage the cutter body and may ignite.
2.
Fully retract and lock trigger. Place the tool in the
carrying case. Store in a cool, dry place.
3.
Fully discharged batteries should be recharged so
that they are ready for use. (See battery charger
instructions.)
Monthly
1.
Thoroughly clean all surfaces.
2.
Check the oil level.
3.
Oil the bolt joints.
Annually or After 10,000 Pressing Cycles
1.
Change the hydraulic oil.
2.
Return the tool to an authorized Greenlee service
center for inspection.
General
Store the tool in the carrying case when it is
not in use.
Checking the Oil Level
1.
Remove the two screws holding the tank housing
cover.
2.
Remove the tank housing cover.
3.
Point the head towards the ground and remove the
oil plug. Refill reservoir if necessary.
4.
Replace the oil plug and the tank housing cover.
Recommended Hydraulic Oils
AVIA HVI 15
Shell Tellus T 15
MOBIL DTE 11
NUTO H 15