RK12CX 12-ton Remote Tool
Greenlee / A Textron Company
4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070
8
Setup
1. Open the tool head.
2. Remove any accessories from the tool head.
3. Install the UA12ID indenter against the ram and lock
in place with the detent.
4. Install the UA12ID anvil into the head and lock in
place with the detent.
Important:
The indenter and anvil must be locked
into place or the detents will be damaged.
5. Visually check the indenter and anvil to ensure that
they are aligned correctly so that they will complete
the crimping operation.
6. Close the tool head.
Press detent and slide
UA12ID indenter into place
as shown. Release to lock.
Press detent and slide UA12ID anvil
into place as shown. Release to lock.
Preparation
For a cUL or UL classified crimp, refer to “Connector
Table” in this instruction manual.
1. Select a proper size and type of connector to
correspond with the wire or cable.
2. Strip the cable to an appropriate length. Follow the
connector manufacturer’s instructions.
Note: Apply an oxide inhibitor, if required.
Refer to the connector manufacturer’s instructions.
3. Clean the die seat area.
Operation—Crimping Using UA12ID Dieless Die Set
Crimping Procedure
1. Insert the cable fully into the connector.
2. Place the connector into the V of the crimping head
as shown below.
Connector
3. If open, close the crimping head. Make sure the
head and latch are fully engaged.
4. For a cUL or UL classified crimp, complete the
number of crimps specified under “Connector
Table” in this manual.
5. For a single crimp, position the connector so the
crimp will be located at the center of the barrel.
For a double crimp, position the connector so two
crimps will be evenly spaced between the connec-
tor marks.
6. Activate the hydraulic power source until the ram
has advanced and the crimp is completed.
Note: To ensure a complete crimp, verify that the
power source has reached 10,000 psi (700 bar).
Refer to the “Periodic Relief Valve Check” in this
manual.
7. Stop the power source and allow the ram to retract.
8. Lift the latch to open the crimping head and remove
the connector.
Note: After completing the last crimp on an aluminum
connector, wipe off the excess oxide inhibitor.
An incomplete crimp can cause a fire.
Use proper die, connector, and cable combinations.
Improper combinations can result in an incomplete
crimp.
Failure to observe these warnings could result in
severe injury or death.