E12CCX 12-ton Battery-powered, High-speed Tool
Greenlee / A Textron Company
4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070
17
Problem
Probable Cause
Probable Remedy
Tool is inoperative.
Dirt, contaminants, etc., in ram area
of tool.
Clean tool.
Crimping tool battery contacts
damaged.
Reform contacts.
Tool components worn or damaged.
Return tool to an authorized
Greenlee service center.
Dead battery.
Charge or replace.
Dies and adapters stop during
operation.
Oil level is low.
Check oil level. Refill reservoir.
Air in hydraulic system.
Pull trigger and hold retract button
simultaneously. Hold for approxi-
mately 10 seconds.
Battery load display flashes
constantly.
Battery charge low.
Charge or replace battery.
Tool loses oil.
Damaged internal seal.
Return tool to an authorized
Greenlee service center.
Oil plug not installed properly.
Refill reservoir and replace plug.
Troubleshooting
Before You Begin
1. Make sure that the battery is charged. Recheck
the battery after several minutes to make sure the
battery is holding its charge.
2. Use a
nonflammable
contact cleaner or pencil
eraser to clean the electrical contacts on the battery
and tool.