GATOR™ LS60 Battery-Powered Punch Driver
Greenlee Textron / Subsidiary of Textron Inc.
14
4455 Boeing Dr., Rockford, IL 61109-2988 815/397-7070
Troubleshooting
Before You Begin
1.
Make sure that the battery is charged. Recheck the
battery after several minutes to make sure the
battery is holding its charge.
2.
Use a NONFLAMMABLE contact cleaner or pencil
eraser to clean the electrical contacts on the battery
and cable cutter.
3.
Reinstall battery and check the tool again.
Tool is inoperative.
Dirt, contaminants, etc., in ram area
Clean tool.
of tool.
Punch driver battery contacts are
Reform contacts.
damaged.
Tool components worn or damaged.
Return tool to an authorized
Greenlee service center.
Ram stops during operation.
Oil level is low.
See Checking Oil Level. Fill reservoir.
Air in hydraulic system.
Pull trigger and hold retract button
simultaneously. Hold for approximately
10 seconds.
Ram stops before punch is
Ram has reached end of travel.
Press retract button. After ram is fully
completely through material.
retracted, tighten punch on draw stud.
Die, material and punch must be snug.
Proceed to punch.
Spacer needed.
Disassemble setup. Add spacer.
Reassemble and punch.
Air in hydraulic system.
Pull trigger and hold retract button
simultaneously. Hold for approximately
10 seconds.
Exceeded rated capacity of tool.
Punch size is too large, or material is
too thick, etc.
Tool loses oil.
Damaged internal seal.
Return tool to an authorized Greenlee
service center.
Oil plug not installed properly.
Refill reservoir and replace plug.
PROBLEM
PROBABLE CAUSE
PROBABLE REMEDY