Statement of Conformity

Greenlee Tools, Inc. is certified in accordance with ISO 9001 (2000) for our Quality 
Management Systems.

The instrument enclosed has been checked and/or calibrated using equipment that is 
traceable to the National Institute for Standards and Technology (NIST).

Maintenance

Electric shock hazard:

Before opening the battery cover or case, remove the leads from external devices and 
shut off the unit.

Failure to observe this warning could result in severe injury or death.

a.    The repair and service of the meter should be accomplished by Greenlee  
       professional maintenance personnel or authorized departments.

b.   Clean the meter case by using dry cloth periodically. Grinding agent and solvent 

should not be used.

Battery Installation and Replacement 

This product uses 3 AAA 1.5V batteries. Please install or replace the batteries by  
following the procedure below:

a.    Turn off the meter and remove the probes

b.    Remove the screws from the battery cover, remove the battery cover, and  
       replace the batteries.

c.    After installing the batteries, replace the battery cover and secure with screws.

www.

.com

[email protected]

1.800.561.8187

Содержание FC-110

Страница 1: ...idad que aparecen en este manual antes de manejar estas herramientas o darles mantenimiento Lire attentivement et bien comprendre toutes les instructions et les informations sur la s curit de ce manue...

Страница 2: ...ex Clamp Meters are hand held testing devices that measure AC current These meters are designed to be placed on or removed from insulated or uninsulated conductors Safety Safety is essential in the us...

Страница 3: ...injury or property damage Read and understand this material before operating or servicing this equipment Failure to understand how to safely operate this tool could result in an accident causing seri...

Страница 4: ...e injury or death Electric shock hazard Do not apply more than the rated voltage between any two input terminals or between any input terminal and earth ground Keep hands and fingers below the barrier...

Страница 5: ...flash when the batteries are low 5 Range Switch Select the appropriate current range for the application Ranges are 30A 300A and 3000A 6 Output Voltage Description Lists the output voltage resolution...

Страница 6: ...g uninsulated conductors do not power on the wire to be tested until the meter has safely clamped the wire 1 Turn off the clamp meter as well as the conductor being measured 2 Unlock the clamp accordi...

Страница 7: ...greater than 3V will display on the AC voltage measuring device Please select the appropriate range 30 00A 300 0A 3000A 7 Improper operation examples a Do not test more than one conductor at a time as...

Страница 8: ...0A Frequency Response 45Hz 500Hz FC 118 Accuracy Additional accuracy range when measuring outside of optimum location when no other electrical or magnetic fields are present Center for optimal measure...

Страница 9: ...Measurement Categories These definitions were derived from the international safety standard for insula tion coordination as it applies to measurement control and laboratory equipment These measureme...

Страница 10: ...vere injury or death a The repair and service of the meter should be accomplished by Greenlee professional maintenance personnel or authorized departments b Clean the meter case by using dry cloth per...

Отзывы: