Operation
1.
See Typical Measurements for illustrations.
2.
See the Test Table for test instructions.
3.
Test the unit on a known functioning circuit or component.
• If the unit does not function as expected on a known functioning circuit, replace the
batteries.
• If the unit still does not function as expected, send the unit to Greenlee for repair.
4.
Take the reading from the unit to be tested. The LEDs illuminate as follows:
LED Table
LED Illuminated
Indication
Tone
DVC-6
DVC-10
LED 1
Positive (+) DC
Positive (+) DC
None
of 12 V or more
of 120 V or more
LED 2
Negative (–) DC
Negative (–) DC
Continuous
of 12 V or more
of 120 V or more
LED 1 and LED 2
AC of 12 V or more
AC of 120 V or more
Warbling
Other Voltage LEDs
Approximate voltage level
—
/ Rx
Continuity or voltage present
*
GFCI
GFCI test in progress
—
DVC-6
LED 1
LED 2
DVC-10
LED 1
LED 2
* Continuous tone for continuity. Tone for voltage is described above.