CMPL-100
19
Accuracy
See the Specifications section for operating conditions.
Accuracy is specified as follows:
±
(a percentage of the r the value of the rightmost
decimal place) at 18
°
C to 28
°
C (64
°
F to 82
°
F), 0% to 80% relative humidity.
Accuracy Table
* Peak detect acquisition time
≤
100 ms
** Input impedance is 1 M
Ω
.
*** Peak detect acquisition time
≤
200 ms
† Sensitivity is 10 V or 10 A.
†† AC-coupled, true RMS measurement,
additional error for crest factors > 1:
Value
Range
Accuracy
Frequency Range
True Power
600.0 kW
±
(2% + 0.5 kW)
40 to 400 Hz
Apparent Power
600.0 kVA
±
(2% + 0.5 kVA)
40 to 400 Hz
0.3 to 1.0
±
3
°
Power Factor
( = 72.5
°
to 0
°
)
10 to 60 Hz
0.0 to 0.3
Not
( = 90
°
to 72.5
°
)
Specified
DCA
999.9 A
±
(2% + 0.5 A)
N/A
ACA††
999.9 A
±
(2% + 1.0 A)
40 to 400 Hz
Peak Current*
999.9 A
±
(2.5% + 1.0 A)
40 to 400 Hz
DCV**
600.0 V
±
(0.75% + 0.2 V)
N/A
ACV** ††
600.0 V
±
(1.2% + 1.0 V)
40 to 400 Hz
Peak Voltage***
600.0 V
±
(2.5% + 1.0 V)
40 to 400 Hz
Continuity
999.9
Ω
±
(1% + 0.5
Ω
)
N/A
Resistance
9.999 k
Ω
±
(1% + 0.005 k
Ω
)
N/A
Frequency†
999.9 Hz
±
(0.5% + 0.5 Hz)
0 to 1 kHz
Crest Factor
Error (% of reading)
1 to 3
0.5%
3 to 5
3%
5 to 7
6%
Содержание CMPL-100
Страница 12: ...12 Typical Measurements cont d True Power Apparent Power Power Factor ...
Страница 32: ...32 Mediciones más comunes continuación Potencia real Potencia aparente Factor de potencia ...
Страница 52: ...52 Mesures types suite Puissance véritable Puissance apparente Facteur de puissance ...
Страница 62: ...Greenlee Textron Subsidiary of Textron Inc 4455 Boeing Dr Rockford IL 61109 2988 815 397 7070 ...
Страница 63: ...Greenlee Textron Subsidiary of Textron Inc 4455 Boeing Dr Rockford IL 61109 2988 815 397 7070 ...