Greenlee 950-M3 Скачать руководство пользователя страница 3

3

4455 Boeing Dr., Rockford, IL 61109-2988    815/397-7070

Greenlee Textron / Subsidiary of Textron

 950-M3 Basic Hydraulic Power Pump

SAVE THESE INSTRUCTIONS

Additional copies of this manual are available upon request at no charge.

• Inspect pump, hoses, couplers and fittings for

wear or damage. Replace worn, damaged or
missing components with Greenlee replacement
parts.

• Do not twist, kink, curl, paint or cut the

hydraulic hoses.

• Wear eye protection when operating this

equipment.

• Disconnect the pump from the power supply,

rotate the release valve lever to AUTO RELEASE
and disconnect the hose from the ram and the
pump before performing any service.

Failure to observe these warnings could result in
severe injury or death.

Electric shock hazard:

• Do not expose power tools to rain.

• Do not immerse the pendant

switch in water or other liquid.

• Do not connect the pump to any system or

system component other than those supplied
by Greenlee and rated at less than 10,000 psi
(68,950 kPa).

• Do not alter the internal high-pressure relief

valve setting.

• Do not use this pump in a hazardous

environment. Hazards include open flame and
flammable liquids or gases.

Failure to observe these warnings will result in
severe injury or death.

Skin Injection Hazard:

High pressure oil easily punctures
skin causing serious injury, gangrene
or death. If injured seek medical help
immediately to remove oil.

Do not use fingers or hands to check
for leaks.

Depressurize hydraulic system
before disconnecting the hose.

• The pump is heavy, weighing up to 75 lbs.

Follow NIOSH work practices for manual lifting.
If in doubt, get help.

• Unplug pump when not in use and when chang-

ing accessories.

• Do not use the hose to pull, lift, or carry the

equipment.

• Always work in an area providing good footing

and support.

• Keep work area well-lit, free of clutter, and dry.

Failure to observe these precautions could result
in injury or property damage.

IMPORTANT SAFETY INSTRUCTIONS

Содержание 950-M3

Страница 1: ...M 848 REV 3 8 97 950 M3 BASIC HYDRAULIC POWER PUMP Read and understand this material before operating or servicing this tool Failure to understand how to safely operate the tool could result in an accident causing serious injury or death Current for all pumps with Serial No code LC ...

Страница 2: ...roperty damage Hazards or unsafe practices which if not avoided COULD result in severe personal injury or death Immediate hazards which if not avoided WILL result in severe personal injury or death SAFETY ALERT SYMBOL The symbol above is used to call your attention to instructions concerning your personal safety Watch for this symbol It points out important safety precautions It means ATTENTION Be...

Страница 3: ... system or system component other than those supplied by Greenlee and rated at less than 10 000 psi 68 950 kPa Do not alter the internal high pressure relief valve setting Do not use this pump in a hazardous environment Hazards include open flame and flammable liquids or gases Failure to observe these warnings will result in severe injury or death Skin Injection Hazard High pressure oil easily pun...

Страница 4: ...tarting engine 2 Check tightness of hose connections before starting engine 3 Check hydraulic oil with dipstick 52 Oil should be within 1 2 of reservoir top 4 Start engine and allow the pump to idle a few min utes This will allow the hydraulic oil to work into moving parts and give prime to the pump Filling Oil Reservoir In order for the pump to operate properly the oil reservoir must be kept fill...

Страница 5: ... entire oil system should be flushed as follows 1 Drain oil from reservoir 2 Fill reservoir with any recommended flushing oil or clean kerosene and operate pump Work the control handle back and forth several times during flushing to wash all foreign particles from the control valve unit Note Do not operate pump for a very long time as system is not designed to operate with flushing oil or kerosene...

Страница 6: ...w 68 Necessary to add oil often Oil leaks Check for broken lines loose fittings or connections If the above corrective measures fail to make the pump function properly it is recommended that you send the pump back to the factory or to an authorized Greenlee service center Under no conditions allow unqualified personnel to attempt to repair the pump particularly the pump block unit or control valve...

Страница 7: ... Rockford IL 61109 2988 815 397 7070 Greenlee Textron Subsidiary of Textron 950 M3 Basic Hydraulic Power Pump 60 SERIAL NO LOCATION A A 15 50 11 43 9 25 10 75 4 3 69 58 56 67 70 21 68 65 66 55 59 61 64 54 62 63 57 53 A ...

Страница 8: ...ng Dr Rockford IL 61109 2988 815 397 7070 950 M3 Basic Hydraulic Power Pump B A B B 22 26 37 9 8 7 33 36 29 23 38 28 27 4 31 3 34 5 6 32 20 10 13 SECTION A A 22 37 26 20 4 25 19 40 1 2 SECTION BB 35 30 10 24 18 15 12 17 16 11 14 39 40 ROTATION 096 106 ...

Страница 9: ...llow 1 19 905 1473 4 Bearing single row unshielded ball 1 20 501 8237 4 Block pump 1 21 502 2701 7 Adapter drive shaft 1 22 500 6111 9 Spring compression 1 23 501 4865 6 Spring compression 1 24 502 1175 7 Screen intake 1 25 905 1472 6 Lok dowel 1 4 x 3 4 2 26 905 0436 4 Ball steel 9 32 diameter 2 27 501 8195 5 Plunger check valve 1 28 905 0677 4 Ball steel 5 32 diameter 1 29 905 0681 2 Ball steel ...

Страница 10: ... 1 Seal oil 1 375 x 2 375 x 312 1 60 905 0734 7 Plug pipe 3 4 NPTF socket 1 61 905 0505 0 Washer lock 323 x 586 x 078 spring 3 62 905 0506 9 Washer lock 388 x 673 x 070 steel 4 63 905 0522 0 Screw cap 5 16 18 UNC x 1 hex head 2 64 905 0523 9 Screw cap 5 16 18 UNC x 1 1 4 hex head 3 65 905 0228 0 Screw cap 5 16 18 UNC x 1 1 2 socket head 1 66 905 0387 2 O ring 437 x 625 x 093 1 67 502 0330 4 Washer...