940 Series Hydraulic Power Pump

Operating Instructions

This pump is designed to operate at 10,000 psi inter-
mittently. For continuous service, as on production
work, the pressure should not exceed 6,000 psi. (This
limitation is for motor protection only.)

Before operating pump, check the following to assure
proper service:

1. Check for proper power connections and for tight-

ness of hose connections before starting pump.

2. Check hydraulic oil with dipstick. Oil should be within

1/2" of reservoir top.

3. Start motor and allow pump to idle a few minutes.

This will allow the hydraulic oil to work into moving
parts and give prime to pump.

For operation of control valves see page 8.

Servicing

Filling Oil Reservoir

The oil reservoir must be kept filled with a good grade of
light hydraulic oil—Greenlee 905 0806.8 hydraulic oil or
equal—in order for the pump to operate properly.

Draining Oil Reservoir

Unscrew and remove 3/4 inch pipe plug (56) from side
of pump base. Turn pump on its side to drain all oil from
reservoir. Be sure to replace plug before refilling reser-
voir with oil.

Flushing System

As long as the pump is used as outlined in the operating
instructions, long, trouble-free performance can be
expected. To maintain this performance, it is absolutely
essential that dirt or other foreign matter be kept out
of the system, as this is the most common cause of
hydraulic system failure. Therefore, when opening up
the pump for any reason, such as making pipe connec-
tions, adjusting pressure or any repair, be sure to
exercise extreme care in cleanliness and to use clean
tools and cloths. If, at any time, dirt is suspected to have
found its way into the system, the entire oil system
should be flushed as follows:

1. Drain oil from reservoir.

2. Fill reservoir with any recommended flushing oil or

clean kerosene and operate pump. Work the control
handle back and forth several times during flushing
to wash all foreign particles from the control valve
unit.

Note: Do not operate pump for a very long time as

system is not designed to operate with flushing
oil or kerosene.

3. Drain flushing oil or kerosene from reservoir and refill

with new oil.

Eight quarts are required, of which 6-1/4 quarts are
usable. A minimum of 1-3/4 quarts must be at the
bottom of the reservoir at all times during operation.
Be sure that your complete operation does not require
more than the usable amount of oil.

To refill or add oil to the reservoir, proceed as follows:

1. Remove vent unit from top of reservoir (B).

2. Add oil to within 1/2" of top of reservoir when ram is

retracted.

3. Install vent unit securely in place.

Check to see that vent unit is not clogged before
attempting to operate pump.

Never use synthetic fluids or fluids with poor lubri-
cating qualities (i.e., brake fluids, etc.), as permanent
injury to the pump will result.

Содержание 940

Страница 1: ... 1997 Greenlee Textron IM 791 REV 1 7 97 Read and understand this material before operating or servicing this tool Failure to understand how to safely operate the tool could result in an accident causing serious injury or death 940 SERIES HYDRAULIC POWER PUMP ...

Страница 2: ...operty damage Hazards or unsafe practices which if not avoided COULD result in severe personal injury or death Immediate hazards which if not avoided WILL result in severe personal injury or death SAFETY ALERT SYMBOL The symbol above is used to call your attention to instructions concerning your personal safety Watch for this symbol It points out important safety precautions It means ATTENTION Bec...

Страница 3: ...Do not connect the pump to any system or system component other than those supplied by Greenlee and rated at less than 10 000 psi 68 950 kPa Do not alter the internal high pressure relief valve setting Do not use this pump in a hazardous environment Hazards include open flame and flammable liquids or gases Failure to observe these warnings will result in severe injury or death Skin Injection Hazar...

Страница 4: ... National Electrical Code The green colored conductor in the cord is the grounding wire which is attached to the metal frame of the unit inside the housing and to the longest blade of the attachment plug cap A special grounding adapter is supplied except in Canada or for use above 150 volts to permit using two wire receptacles until the correct receptacle is installed The green grounding wire exte...

Страница 5: ...y essential that dirt or other foreign matter be kept out of the system as this is the most common cause of hydraulic system failure Therefore when opening up the pump for any reason such as making pipe connec tions adjusting pressure or any repair be sure to exercise extreme care in cleanliness and to use clean tools and cloths If at any time dirt is suspected to have found its way into the syste...

Страница 6: ...2 approx Motor Maintenance If the pump motor is in need of repair it should be done by the manufacturer of the motor or a qualified service center Correcting Minor Hydraulic Problems The hydraulic unit should be observed constantly for out of the ordinary performance and unusual noises If any of these are present shut off pump and take corrective steps immediately to avoid possible expen sive repa...

Страница 7: ...mp without screens as particles of dirt will be sucked into pump and valve mechanisms seriously damaging valve seats Unable to reach pressure Same as above Same as above Necessary to add oil often Oil leaks Check for broken lines loose fittings or connections Noise in hydraulic system Air in system Low in oil Add oil page 5 Run pump to work out air If the above corrective measures fail to make the...

Страница 8: ... ram is held stationary under pressure with motor running when the control handle is in Neutral position The control valve has three positions Advance turn control handle counterclockwise to extreme position Neutral or Hold turn control handle clockwise to middle position and Return turn control handle clockwise to extreme position When the control handle is in Neutral position the pump is unloade...

Страница 9: ...9 4455 Boeing Dr Rockford IL 61109 2988 815 397 7070 Greenlee Textron Subsidiary of Textron 940 Series Hydraulic Power Pump 940 TB 940 TA 940 SA 940 940 BASIC C D E G F 940 Series Pumps ...

Страница 10: ...Greenlee Textron Subsidiary of Textron 10 4455 Boeing Dr Rockford IL 61109 2988 815 397 7070 940 Series Hydraulic Power Pump 49 54 42 52 41 47 A 38 43 39 46 53 50 27 29 48 45 51 940 Series Pumps cont d ...

Страница 11: ...11 4455 Boeing Dr Rockford IL 61109 2988 815 397 7070 Greenlee Textron Subsidiary of Textron 940 Series Hydraulic Power Pump 36 B 5 37 9 50 10 75 SECTION CC 37 56 40 44 55 940 Series Pumps ...

Страница 12: ... of Textron 12 4455 Boeing Dr Rockford IL 61109 2988 815 397 7070 940 Series Hydraulic Power Pump 2 28 19 14 5 24 6 17 7 8 31 13 34 26 18 23 28 1 33 22 16 23 12 11 30 9 20 3 4 25 15 10 35 32 21 SECTION BB 940 Series Pumps cont d ...

Страница 13: ...8 Screw 10 32 NF x 3 4 Socket Head Cap 4 26 905 0681 2 Ball 3 8 Dia 1 27 905 0685 5 Washer 8 Lock 4 28 905 0824 6 Plug 1 16 NPT Pipe 2 29 905 0994 3 Screw 8 32 NC x 1 1 4 Socket Head Cap 4 30 502 2611 8 Roller 125 x 750 30 31 905 0912 9 O Ring 1 2 x 5 8 x 1 16 1 32 905 0320 1 Seal 1 3 8 ID x 2 3 8 OD x 7 16 Thick Oil 1 33 905 1097 6 O Ring 3 x 3 1 4 x 1 8 1 34 905 1111 5 Screw 7 16 20 NF x 1 2 Cup...

Страница 14: ...940 501 5679 9 Hydraulic Pump includes A through 56 plus C Key Control No Description C 501 6152 0 Hose Connection Unit 940 SA 501 5680 2 Hydraulic Pump includes A through 56 plus D Key Control No Description D 501 5644 6 SA Control Valve Unit see IM 790 for parts 940 TA 501 5681 0 Hydraulic Pump includes A through 56 plus E Key Control No Description E 501 2106 5 TA Control Valve Unit see A 684 I...

Отзывы: