93-105 / 00408
7
Advanced Features
Relative Mode (REL
∆
)
1. Measure a value according to the operating instructions.
2. Press REL
∆
. The REL icon will appear. The present value will be used as a reference value
and the display will change to all zeros.
3. Measure a new value. The display will show the difference between the stored reference
value and the present value.
4. Press REL
∆
for two seconds to exit Relative Mode.
When measuring resistance, use the relative mode to use the resistance of the leads as a
reference value. This is the same as “zeroing” an analog meter. Then use the meter
according to the instructions to find the actual resistance value of a resistor or circuit.
MIN MAX
1. Measure a value in autoranging mode according to the operating instructions.
2. Press MIN MAX once and the
and MIN icons will appear; press MIN MAX again and
the MAX will appear (MIN will disappear). The meter will begin to record the input.
3. (Optional) Press HOLD
to stop recording; the display will be held constant. Press
HOLD
again to resume recording; the display will become active again and the
minimum or maximum value will be updated.
4. Press MIN MAX to exit the MIN MAX mode.
Note: The Auto Power Off feature will shut the meter off after approximately 30 minutes.
Using MIN MAX and Hold: While using the Hold feature, press MIN MAX to go directly into
MIN MAX recording mode.