Greenlee Textron / Subsidiary of Textron Inc.
Motor Rotation Indicator
6
Features
1. Test Button: Turns on the test instrument.
2. ON LED: Illuminates when Test Button
is pressed; indicates the tester is ON
3. CORRECT LED: Indicates that the motor
connections correspond to the direction
of motor rotation
4. INCORRECT LED: Indicates that the
motor connections do not correspond
to the direction of motor rotation
Do not connect the motor rotation leads
to a source of voltage or current.
Damage to the test instrument can result.
3. Connect the three test leads of the test
instrument to the terminals or leads of
the motor.
Motor Rotation Operation
1. Press the Test Button. If the green ON
LED does not illuminate, replace the
battery.
2. Plug the test leads into the corre-
sponding jacks of the test instrument.
3
4
2
1