Open Plenum Array

1

Document 484885 

Model OPA

Open Plenum Array

Installation, Operation and Maintenance Manual

Please read and save these instructions for future reference. Read carefully before attempting to assemble, install, 
operate or maintain the product described. Protect yourself and others by observing all safety information. Failure 
to comply with these instructions will result in voiding of the product warranty and may result in personal injury 
and/or property damage.

DANGER

Always disconnect, lock and tag power source before 
installing or servicing. Failure to disconnect power 
source can result in fire, shock or serious injury.

CAUTION

When servicing the fan, motor may be hot enough 
to cause pain or injury. Allow motor to cool before 
servicing.

CAUTION

Precaution should be taken in explosive atmospheres.

DANGER

Pour écarter les risques d’incendie, de choc électrique 
ou de blessure grave, veiller à toujours débrancher, 
verrouiller et étiqueter la source de courant avant 
l’installation ou l’entretien.

ATTENTION

Lors de toute intervention sur la soufflante, le moteur 
peut être suffisamment chaud pour provoquer une 
douleur voire une blessure. Laisser le moteur refroidir 
avant toute maintenance.

ATTENTION

Faire preuve de précaution dans les atmosphères 
explosives.

Only qualified personnel should install this array. 
Personnel should have a clear understanding of these 
instructions and should be aware of general safety 
precautions. Improper installation can result in electric 
shock, possible injury due to coming in contact with 
moving parts, as well as other potential hazards. If more 
information is needed, contact a licensed professional 
engineer before moving forward.
1.  Follow all local electrical and safety codes, as well as 

the National Electrical Code (NEC), the National Fire 
Protection Agency (NFPA), where applicable. Follow 
the Canadian Electric Code (CEC) in Canada.

2.  The rotation of the wheel is critical. It must be free 

to rotate without striking or rubbing any stationary 
objects.

3.  Motor must be securely and adequately grounded.
4.  Do not spin the wheel faster than max cataloged 

RPM. Adjustments to fan speed significantly effects 
motor load. If the fan RPM is changed, the motor 
current should be checked to make sure it is not 
exceeding the motor nameplate amps.

5.  Do not allow the power cable to kink or come in 

contact with oil, grease, hot surfaces or chemicals. 
Replace cord immediately if damaged.

6.  Verify that the power source is compatible with the 

equipment.

Model OPA

General Safety Information

Содержание OPA

Страница 1: ...ser le moteur refroidir avant toute maintenance ATTENTION Faire preuve de précaution dans les atmosphères explosives Only qualified personnel should install this array Personnel should have a clear understanding of these instructions and should be aware of general safety precautions Improper installation can result in electric shock possible injury due to coming in contact with moving parts as wel...

Страница 2: ...he array and accessories is indoors above grade in a low humidity atmosphere which is sealed to prevent the entry of blowing dust rain or snow Temperatures should be evenly maintained between 30 F 1 C and 110 F 43 C wide temperature swings may cause condensation and sweating of metal parts All accessories must be stored indoors in a clean dry atmosphere Remove any accumulations of dirt or debris a...

Страница 3: ...protect personnel Refer to local codes for requirements as to the number type and design Fully secure the wheel before performing any maintenance The wheel may start free wheeling even if all electrical power has been disconnected Before the initial start up or any restart check the following items to make sure that they are installed and secure Do not spin the wheel faster than the maximum catalo...

Страница 4: ... others All supply and or signal wiring should be secured to the array structure CAUTION When installing an array ensure the proper protective devices are used to protect personnel from moving parts and other hazards A complete line of protective accessories are available from the manufacturer Installation Example of Shim Stock Electrical Connections Before electrical connections are made the supp...

Страница 5: ...77 Taper Lock Bushing Installation Removal To Install Taper Lock Bushings 1 Clean shaft bore and outside of bushing and bore of hub taking bushings from hub if already assembled Remove any oil grease and dirt 2 Place hub onto shaft Slip bushing onto shaft and into hub Oil threads and points of setscrews or threads and under heads of capscrews DO NOT lubricate the hub bore or the outside of the bus...

Страница 6: ...rews and locking collars on the array bearings drive motor base and accessories for tightness 5 Rotate the wheel by hand and assure no parts are rubbing Remove any dirt or debris that may have accumulated during installation 6 Check all guarding if supplied for being securely attached and not interfering with rotating parts 7 Check all electrical connections for proper attachment 8 Check for obstr...

Страница 7: ...or at least bumped every thirty days It is preferred that each array is run as this causes all electrical and mechanical components to get up to temperature displacing any formed condensation redistributes load on bearings and redistributes grease in the bearings motor and shaft bearings CAUTION Always check the fan RPM when adjusting the operating frequency Do not exceed maximum class fan RPM of ...

Страница 8: ...el rubbing inlet Adjust wheel and or inlet cone Tighten wheel hub or bearing collars on shaft Wheel unbalance Clean all dirt off wheel Check wheel balance rebalance in place if necessary Low CFM Fan Check wheel for correct rotation Increase fan speed Duct system Check duct installations with poor inlet or discharge configurations High CFM Fan Decrease fan speed High Horsepower Fan Check rotation o...