Greenheck ATI Скачать руководство пользователя страница 8

Greenheck warrants this equipment to be free from defects in material and workmanship for a period  
of  one  year  from  the  purchase  date.  Any  units  or  parts  which  prove  defective  during  the  warranty  
period will be replaced at our option when returned to our factory, transportation prepaid. Motors are 
warranted by the motor manufacturer for a period of one year. Should motors furnished by Greenheck 
prove  defective  during  this  period,  they  should  be  returned  to  the  nearest  authorized  motor  service  
station. Greenheck will not be responsible for any removal or installation costs.

As  a  result  of  our  commitment  to  continuous  improvement,  Greenheck  reserves  the  right  to  change 
specifications without notice.

P.O. Box 410 • Schofield, WI 54476-0410 • Phone (715) 359-6171 • greenheck.com

Building Value in Air

Our Warranty

Prepared to Support

Green Building Efforts

Greenheck delivers value 
to mechanical engineers by 
helping them solve virtually 
any air quality challenges 
their clients face with a 
comprehensive selection of 

top quality, innovative air-
related equipment. We offer 
extra value to contractors 
by providing easy-to-install, 
competitively priced, reliable 
products that arrive on time.  

And building owners and 
occupants value the energy 
efficiency, low maintenance 
and quiet dependable operation 
they experience long after the 
construction project ends.

Roof Curbs Rev. 4 August 2008 RG 

Copyright © 2008 Greenheck Fan Corp.

Typical Installation

Greenheck's straight-sided roof curbs are designed for general exhaust or supply 
applications.

General Flashed Roof Installation:

1.  Remove roofing material where roof penetration is to be made and provide a 

10-inch wide clearance around perimeter of hole in roof.

2.  Apply roofing cement around roof opening.
3.  Place and center roof curb over hole in roof so it sits on roofing cement. Make 

sure the roof curb is placed over an adequate support structure to handle the 
weight and wind load of curb and fan assembly.

4.  Secure roof curb to roof deck using a minimum of three lag screws, anchor bolts, 

or suitable metal fasteners per side and two per corner (fasteners by others).

5.  Install insulation if required.
6.  Field flash – flashing should extend at least 4 inches beyond the horizontal flange 

on roof curb. Flashing should also extend over the top flange surface where there 
is a wood nailer for a leak resistant installation.

7.  Apply Curb Seal (rubber gasket) to the top of roof curb to seal fan or ventilator to 

curb to prevent air leaks and water penetration and to reduce the transmission of 
vibration from fan to building.

8.  Place fan or ventilator onto roof curb and center.
9.  Secure fan’s curb cap to the roof curb using a minimum of two lag screws, anchor 

bolts, or suitable metal fasteners per side (fasteners by others).

Notes:
  •  For rubber roofs, refer to roof manufacturer for roof curb installation.
  •  No replacement parts available.
  •  For installation of specialty curbs and high wind curbs, see CAPS for installation details.

Содержание ATI

Страница 1: ...Roof Curbs Extensions and Equipment Supports August 2008 ...

Страница 2: ...dictating manufacturing time Your custom product configuration can be manufactured in one three five or ten days then shipped to your job site Leading Edge Technical Support When you need extensive product information look no further Greenheck products are supported by the industry s best product literature including catalogs Installation Operation and Maintenance Manuals IOM electronic media Comp...

Страница 3: ... allow the damper to be placed in the tray and fastened Optional Coatings A wide variety of coatings and colors are available Decorative coatings are available in sixteen standard colors Protective coatings are available in five electrostatically applied powders providing a selection for most environments All coatings and relative resistance charts can be found in Greenheck s Product Application G...

Страница 4: ... flashing flange then roofed and flashed to the top of the wood nailer for weather tightness For pitched or ridged applications use models GPIP GPIR GPFP or GPFR Model GPS consists of a fully welded body and 1 inch insulation Model GPS is available in heights of 8 to 18 inches Model GPR with raised cant This curb is designed for use on flat insulated roof decks It is mounted directly to the deck s...

Страница 5: ...CE The VCE vented curb extension is typically used in kitchen applications where the vents allow hot air and gases to escape between the ductwork and the roof curb Designed for use with an 8 inch high roof curb and Greenheck fan models CUBE CUE or USGF to provide the required 40 inch minimum discharge height above the roof line per NFPA 96 Model VCE consists of galvanized steel or welded aluminum ...

Страница 6: ...or roof decks and consist of continuous welded seams Model ATI for use on flat non insulated roofs ATIP for pitched roofs and ATIR for ridge double pitched roofs They are mounted directly to the roof deck with a 2 inch flashing flange before the insulation is applied then roofed and flashed to the top of the wood nailer for weather tightness Model ATE Sound attenuating curb extensions are designed...

Страница 7: ...hes larger than the curb AD dimensions Minimum adapted amount 11 2 inches Maximum adapted amount 10 inches Adapter Fan curb cap is smaller than existing curb A B 2 1 2 in 1 500 Fan Curb Fan Curb Curb Adapt Down A 2 1 2 in Curb Cap W L AD Curb Cap W L 1 2 in Adapted Curb Cap W L Reducer Fan curb cap is larger than existing curb GPF GPI FLANGED CURB WOOD NAILER CURB 1 in 1 in Dimensional Data Model ...

Страница 8: ...08 RG Copyright 2008 Greenheck Fan Corp Typical Installation Greenheck s straight sided roof curbs are designed for general exhaust or supply applications General Flashed Roof Installation 1 Remove roofing material where roof penetration is to be made and provide a 10 inch wide clearance around perimeter of hole in roof 2 Apply roofing cement around roof opening 3 Place and center roof curb over h...

Отзывы: