Installation, Operation and Maintenance Instructions

Safety WaRNING:

 

Improper installation, adjustment, alteration, 
service or maintenance can cause property damage, 
injury or death. Read the installation, operating, 
and maintenance instructions thoroughly before 
installing or servicing this equipment.

This manual is the property of the owner, and is required 
for future maintenance. Please leave it with the owner 
when the job is complete.

WaRRaNty

Greenheck warrants this equipment to be free from 
defects in material and workmanship for a period of one 
year from the purchase date. Any units or parts which 
prove to be defective during the warranty period will 
be repaired or replaced at our option. Greenheck shall 
not be liable for damages resulting from misapplication 
or misuse of its products. Greenheck will not be 
responsible for any installation or removal costs. 
Greenheck will not be responsible for any service work 
or backcharges without prior written authorization. 

ReceIvING aNd HaNdlING

Upon receiving dampers, check for both obvious and 
hidden damage. If damage is found, record all necessary 
information on the bill of lading and file a claim with 
the final carrier. Check to be sure that all parts of the 
shipment, including accessories, are accounted for.

Dampers must be kept dry and clean. Indoor storage 
and protection from dirt, dust and the weather is highly 
recommended. Do not store at temperatures in excess of 
100°F.

International Maritime fire test Procedure 

code 

   USCG Type Approved

             Approval Number  164.139/0007/0

Part number 464603 

IMO-XXX & SSIMO-XXX series

fire and combination fire Smoke dampers 

vertical or Horizontal Mount

Содержание 464603

Страница 1: ...able for damages resulting from misapplication or misuse of its products Greenheck will not be responsible for any installation or removal costs Greenheck will not be responsible for any service work or backcharges without prior written authorization Receiving and Handling Upon receiving dampers check for both obvious and hidden damage If damage is found record all necessary information on the bil...

Страница 2: ...ated a minimum of 6 in 152mm on the damper side and 18 in 457mm on the non damper side see figures 1 4 Any US Coast Guard type approved insulation with an A60 rating can be used The insulation is to be installed on the duct with 0 106 in 2 7mm steel pins and 1 12 in x 1 24 in x 0 4 in 28mm x 31mm x 10mm steel clips 2 Attaching Damper to Duct The damper can be installed to the duct using either bol...

Страница 3: ...code RATINGS Integral Switch Type Single Pole double throw Electrical Capacity 10 Amps 1 3 hp 120 or 240 Vac 1 2 Amp 125 Vdc 1 4 Amp 250 Vdc 5 Amps 120 Vac L lamp load 1 0 Amps 24 Vac 1 5 Amps 24 Vdc Temperature Limit 165 F standard primary sensor 212 F optional primary sensor L1 DAMPER INDICATOR LIGHTS L2 CLOSED POSITION OF THE DAMPER A BLUE MARKER INDICATE THE THE SWITCH WIRES WRAPPED WITH NOTE ...

Страница 4: ...oting The following is a possible cause and correction list for common concerns with the dampers Damper Maintenance Dampers do not typically require maintenance as long as they are kept dry and clean If cleaning is necessary use mild detergents or solvents If lubrication is desired for components such as axle bearings jackshaft bearings and jamb seals do not use oil based lubricants or any other l...

Отзывы: