background image

Issu

e n

o: 

70

47

69

WEST  ROAD  .  HARLOW

ESSEX  .  CM20  2BG  .  UK

[email protected]

www.greenbrook.co.uk

Rated Voltage:

100-240V AC

50Hz

Colour Temp:

6,000K

Class:

I

IP Rating:

IP54

Switching Cycles:

100,000

Total Lumens:

LEDFLSPIR10W/B

1,000 / 100 lm/W

LEDFLSPIR20W/B

2,000 / 100 lm/W

LEDFLSPIR30W/B

3,000 / 100 lm/W

LEDFLSPIR50W/B

5,250 / 105 lm/W

LEDFLSPIR100B

10,000 / 100 lm/W

Beam Angle:

120º

PIR Detection Distance:

2 - 8m

PIR Time Lag:

12s - 7m

Life Span:

> 35,000 hours

Conforms to:

EN60598, EN62031,

EN61500, EN61547 

&  EN55015

TECHNICAL INFORMATION

GUARANTEE

Your GreenBrook PIR LED Slimline Floodlight 

is guaranteed for 3 years from 

the date of purchase. 

This is in addition to your statutory rights.

PLEASE KEEP THESE INSTRUCTIONS 

SAFE FOR FUTURE REFERENCE

The motion sensor can be adjusted 340º from left to right

and adjustable through 180° up and down.

Pan +170,0,-170

Tilt +90,0, -90

DIAL FUNCTION

MAINTENANCE:

Keep the glass front clean with a soft cloth. There are no

user serviceable parts contained within fitting. Any 

disassembly or modification will invalidate the warranty.

DISPOSAL:

At the end of the product’s life this product must not be

disposed of in landfill. 

Local recycling guidance should be sought for  disposal.

There are no hazardous materials contained therein.

ADJUSTING THE LUX CONTROL LEVEL

The Lux control module has a built-in photocell that detects 

daylight and darkness.

(  ) position denotes that the lamp will be turned on by the

PIR during day and night.

(  ) position denotes that the lamp will be turned on by PIR

only at night.

A Lux range of 5 - 2000 Lux can be selected. The desired

Lux level can be achieved by adjusting the Lux knob.

ADJUSTING THE DURATION TIME

The duration time is the length of time that the PIR Detector

switches the light ‘on’ after activation. The duration time

can be adjusted from approx 12 seconds up to 7 minutes.

Rotating the TIME knob from (+) to (-) will reduce the 

duration time.

ADJUSTING SENSITIVITY

This control allows the user to adjust the level of movement

required, to trigger the device (+) will increase the 

sensitivity of the unit. (-) will decrease the sensitivity of the

unit.

Lux: Sets the light 

sensitivity of the sensor
Time: Sets the 

interval time

Sens: Sets the 

response level to movement

POSITIONING OF SENSOR