background image

Assembly Manual

Содержание Biocheck-in

Страница 1: ...Assembly Manual...

Страница 2: ...2 ASSEMBLY MANUAL 2020...

Страница 3: ...aning and maintenance 1 7 Biocheck in 1 8 Components 1 9 Settings 1 10 APP 1 11 Bluetooth Pairing 1 Introduction PAGE 04 2 Prepare device for first use 3 Additional information 2 1 Installation 2 2 Tu...

Страница 4: ...n unstable location or with a very uneven floor Do not expose the biocheck in to rain or to extreme weather conditions We recommend placing the device away from direct sunlight Place the Biocheck in o...

Страница 5: ...ug socket or battery is damaged If the product is damaged by a drop or impact If the battery is placed with a power source 1 Plug the device into an outlet under the following conditions If the batter...

Страница 6: ...ASSEMBLY MANUAL 2020 1 5 6 7 8 9 10 11 3 4 Card reader Temperature sensor Alcohol Gel outlet Door lock USB cable Power bank Gel deposit Button ON OFF Menu button Select button 1 7 Biocheck in 2 Displ...

Страница 7: ...ect buttons located inside the compartment allow you to calibrate the Biocheck in However for simplified use download the Biocheck in APP www biocheckin pt Button A Menu activates the navigation optio...

Страница 8: ...omb 3 B BRIGHTNESS Screen brightness Allows you to adjust the brightness between 10 minimum and 100 maximum brightness in 10 iterations Note Pressing the menu button after the last option exits Menu m...

Страница 9: ...button WorkFlow E you can change and select different workflows modes the Standdard mode is current usage mode 7 The Screen Brightness button F can increase or decrease the brightness of the screen 8...

Страница 10: ...10 1 ASSEMBLY MANUAL 2020...

Страница 11: ...that at that moment the application of Biocheck in becomes active in the device closest to you Once the Bluetooth of the smartphone to which it was paired is turned off the Biocheck in screen will dis...

Страница 12: ...rting the assembly make sure you have the correct tools 2 Two people are required for transportation and assembly 3 During assembly place items on a mat or protected surface never on the floor 4 In ca...

Страница 13: ...13 2 ASSEMBLY MANUAL 2020 1 Place the stainless steel base and foot in a horizontal plane 2 Align the foot holes with the base 3 Place the iron base aligned with the same holes...

Страница 14: ...14 2 ASSEMBLY MANUAL 2020 4 Tighten the washer screw joining the base to the foot 5 Place the mdf base aligned with the holes 6 Screw and base 2 x 8 x 1 x...

Страница 15: ...15 2 ASSEMBLY MANUAL 2020 7 Align the levelers with the holes 8 Screw the levelers 9 Check the piece stability 4 x 1 x 8 x...

Страница 16: ...16 2 ASSEMBLY MANUAL 2020 10 Place the piece vertically 11 Align the shore holes with the foot 12 Tighten the washer screw joining the back to the foot...

Страница 17: ...ASSEMBLY MANUAL 2020 13 Check the piece stability 14 Place the hinges of the box in line with the groove on the back 15 Overlap the two elements and perform with a pressure movement on the tip of the...

Страница 18: ...MANUAL 2020 16 Stabilize the hinge alignment at point A and apply pressure on point B until it clicks into place 17 Fully charge the power bank before the first use 18 Place the power bank in the com...

Страница 19: ...USB cable in the compartment to the respective power bank socket 20 Unscrew the tank cap 21 Remove the tank from inside the compartment Do not fill the tank while it is in the compartment You may dama...

Страница 20: ...23 Place the tank inside the compartment 24 Screw on the cap correctly so that there is no leakage of gel Check if the alcohol tube is not attached to the bottom or sides of the tank The tube must be...

Страница 21: ...kin pt 26 To complete the installation of the gel tank it is necessary to prime the pump Open the Biocheck in application and select the option Maintenance Prime Pump or optionally press button B and...

Страница 22: ...22 2 ASSEMBLY MANUAL 2020 28 After priming the pump close the device 29 Join the front part with the back and lock the lock on top of the device 30 Check that the device is properly closed...

Страница 23: ...it 32 Optionally the device can be connected directly to the mains without using the power bank A 5V 2A AC DC transformer supplied with the equipment was used 33 On the device s back is a USB C port...

Страница 24: ...n the wrist keeping it facing up 4 cm from the hand The skin must be clean and dry in case of being wet wipe with a dry cloth first Do not use the device if the skin is too hot or cold due to the infl...

Страница 25: ...y there will be a brief beep The device will also indicate with the text LO if the distance between pulse and the sensor is greater than 135cm or if the temperature value is less than 32 6C 38 The blu...

Страница 26: ...OFF the power bank inside will shut down automatically and restart in when the Biocheck in is restarted 2 In case the device is connected directly to the current only turn the article off in the ON OF...

Страница 27: ...e body temperature is lower and increases throughout the day until night 3 2 Problems Solutions If you want to start Biockeck in on off switch and it indicates with audible signal beep the start but d...

Страница 28: ...taxo Portugal Opening hours Monday to Friday 9 19 h Telephone 351 243 70 90 80 Whatsapp Wechat 351 967 952 518 Email info greenapple pt Web www greenapple pt Instagram greenapple design interiors Bioc...