background image

INSTALLATION AND OPERATION

FOR: R

Initial items …………
Humidifier basics……
Installing humidifier
Sequence of
Typical System Diagrams
STS System Diagrams….
Wiring diagram
Trouble Shooting
Mainte
Controller info
Wet Switch ………………
Parts List …………………
More Components ……..

VS.10.13

INSTALLATION AND OPERATION

RAH – 1000 & 1500 Series

Table of Contents

Initial items …………..…

1

Humidifier basics………

2

Installing humidifier……

3

Sequence of Operation .. 6
Typical System Diagrams 7
STS System Diagrams…. 9
Wiring diagrams …………. 12
Trouble Shooting ……….. 15
Maintenance ……………

17

Controller info …………..

18

Wet Switch ………………

21

Parts List ………………… 22
More Components ……..

23

1

INSTALLATION AND OPERATION

Содержание RAH-1000 series

Страница 1: ...o Wet Switch Parts List More Components VS 10 13 INSTALLATION AND OPERATION RAH 1000 1500 Series Table of Contents Initial items 1 Humidifier basics 2 Installing humidifier 3 Sequence of Operation 6 T...

Страница 2: ...gs The following guidelines should be adhered to The DTA should be placed in a straight section of duct work with at feet up stream and downstream with no obstructions branch take offs or If a vertica...

Страница 3: ...r downstream of the DTA for at least 3 ft in either direction Sealant can be used on the flange if desired for complete seal Once you have located the Generator in a clear and accessible location use...

Страница 4: ...tem The supply side will consist of Black tubing Locate the Yellow drain line and place in an appropriate area for drainage NOTE DRAIN MUST BE OPERABLE EVEN IF THE HUMIDIFICATION SEASON IS MONTHS AWAY...

Страница 5: ...domestic water supply and the humidifier supply lines If there are any questions or issues please contact your Factory Representative If the system was provided with a controlling humidity sensor then...

Страница 6: ...m If your model has a timer delay relay go to that section in this Manual for more info In this configuration the Digital Controller governs the humidifier The electronic humidity sensor is wired back...

Страница 7: ...H 10 00 G E N E R AT O R Install Generator at angle so door can swing completely open REDUCE TO 3 AT PANEL FAN FRONT VIEW FROM CLOSET DOOR SIDE VIEW W ATER PURIFICATION STATION STORAGE TANK Note water...

Страница 8: ...GURE 1 TYPICAL LAYOUT 10 RETURN DUCT ELECTRONIC AIR FILTER SUPPLY AIR REENSAIR CONTROL PANEL 15 Amp Cir 20 x20 x12 WATER PURIFICATION STATION STORAGE TANK TO DRAIN DRAIN ALL LOW POINTS COLD WATER 3 L...

Страница 9: ...1030 1050 STS HL Supply Hi Limit Switch AFS Air Flow Switch low voltage multi conductor cable RO WATER STATION 3 GAL STORAGE RETURN SIDE APPLICATION 3 8 OD water drain 3 8 Main to Humidifiers B C E H...

Страница 10: ...Flow Switch RAH 1090 STS low voltage multi conductor cable RO WATER STATION 3 GAL STORAGE TANK 1 4 OD water drain SUPPLY SIDE APPLICATION Please Note One 1 RO Water Station can serve FOG ON ON OFF 00...

Страница 11: ...DUCT STS UNIT STS UNIT STS UNIT POSSIBLE LOCATIONS SUPPLY AIR FEED SUPPLY DUCT AC UNIT DUCT EXT STS UNIT STS UNIT STS UNIT DTA DTA DTA SUPPLY AIR FEED 11 PLAN VIEW...

Страница 12: ...SWITCH HI LIMIT 12B CR3 FLOAT SWITCH SAFETY HHLS FLS CR2 11 12 12A 12C 13 17 16 18 13 TIMER RELAY FCR STS WIRING with CONTROLLER DENOTES ITEM LOCATION OUTSIDE OF CONTROL PANEL GENERATOR 7 CR4 RH SENS...

Страница 13: ...11 12 12A 12C 13 17 16 18 13 TIMER RELAY FCR CR1 STS WIRING for REMOTE CONTROL DENOTES ITEM LOCATION OUTSIDE OF CONTROL PANEL GENERATOR 120VAC 7 CR4 2 10 N 2 Power On R 500 VA 7 6 STS BOX 2 WET SWITCH...

Страница 14: ...HI LIMIT 12B CR3 FLOAT SWITCH SAFETY HHLS FLS CR2 11 12 12A 12C 13 17 16 18 13 TIMER RELAY FCR STANDARD RAH WIRING WITH CONTROLLER DENOTES ITEM LOCATION OUTSIDE OF CONTROL PANEL GENERATOR CR4 RH SENSO...

Страница 15: ...has closed after properly sensing that air is moving in the duct Verify that the HiLimit switch circuit is closed Check the Wet Switch and verify that the green LED on the switch is lit If it is red...

Страница 16: ...here is a call for heat There is a dry contact relay in the panel for exactly this purpose Contact the Installer to verify that he utilized this relay and that the control sequence on the blower syste...

Страница 17: ...and making sure all the UPC discs that should be running are indeed doing so You may do this by observing the operation with a flash light and peering through the plastic lid or taking the lid off see...

Страница 18: ...DIGITAL CONTROLLER DIGITAL CONTROLLER 18...

Страница 19: ...19...

Страница 20: ...ir humidifiers have their controllers pre programmed in the Factory but if it is somehow lost here is the access and settings A To Access the Initial Setting Mode press button for 3 seconds Here are t...

Страница 21: ...21...

Страница 22: ...Socket 6047 Idec Single Pole Relay 6048 Idec Single Pole Socket PARTS LIST Item Description 2 4 MHz Nebulizer Board Model 579R3 304SS with welds stand brackets top flange w PEMS and bottom hole Model...

Страница 23: ...y or Factory Representative for current pricing Plastic Fan Guard for 4 69 Fan Bulkhead Conn 1 4T x 1 8MPT Brass Part B 400 11 2 clear w paper back in square ft units 10 Amp fuse 12 32 dia time delay...

Отзывы: