Owner's Manual
Operation Instructions
1. LED indicator and seven-segment digital display
Connect the charger to the battery. Turn on the mains. The charger enters the charging mode (the battery type indicator shows the default battery
type). The status indicator - % Percent, Battery Voltage, Charging Current and the seven-segment digital display will show the charging status.
Maintenance Instructions
1.
Do not expose charger to oil, dirt, mud or direct heavy water spray when cleaning vehicle.
2.
The enclosure of the charges has been tested successfully to IEC 60529, meeting IP66
or IP67 (see silk screen of
the device
).
3.
If the detachable input power supply cord set is damaged, replace with a cord that is a safety approved detachable cord, 3 conductor, 1.5
mm² minimum, and rated appropriate for use in the country of destination and, on the other end, an output grounding type IEC 60320 C14 plug.
Product Specifications
% Percent:
Battery capacity % indicator. i.e. 10, 20, 30…… 100 (%)
Battery Voltage (V)
: Battery voltage indicator. i.e. 24.0(V)
Charging Current (A):
Charging current indicator. i.e.15 (A)
Model
GPCC1524
DC Output
Voltage-Range(V)
0-34V
Current-Range(V)
0-15A
Output Power(W)
510W
Power Error(%)
1%
Applicable to Battery
AGM, WET, GEL, Lithium
Reverse Polarity
Electronic protection-auto-reset
Short Circuit
Electronic protection-auto-reset
AC Input
Voltage-Range(V)
100-240V
Frequency(Hz)
50-60Hz
Current-max(A)
5
A
Full Load AC Power Factor
>0.98
Dimensions
22.6
*15.2*8.1cm
Weight
2.5KG
Operating Temperature
-40
℃
~+65
℃
Storage Temperature
-40
℃
~+70
℃
3.
Status indicator and seven-segment digital display:
4.
The instruction for cable connection:
1 Connect the battery.
2 Interlock Cable (When charger is charging, the interlock
cables will form an open circuit with no voltage. When charger is not charging, the
interlock cable will form a short circuit with no voltage).
3
Connect AC input wires.
4 Connect CANBUS or LED light wire (Optional function)
Warning:
Assure the battery connection cable is
well connected with the charger before it is connected to the battery. Otherwise, the
battery short circuit may occur and cause personal injury or damage to the battery.
Seven-segment
digital display
fault code Fault Cause
Solution
E01
The battery is not well connected
or battery reversely connected or
battery damaged.
1)
Check battery connection is correct.
2)
Check charger connection is correct.
3)
Check each battery is good..
E02
Abnormal AC Power Input (Voltage).
1)
Check AC input cord is connected between charger and AC outlet.
2)
Make sure AC plug is tightly inserted into AC outlet.
E03
Charger High Temperature
Protection.
1)
Charger shuts down and enters protection mode due to charger/environmental
temperature is too high. Please place the charger in a well-ventilated environment.
2)
Disconnect the charger and wait for 15-20mins before reconnecting for charging.
E04
Battery High
Temperature Protection.
1) Charger will reduce current even stop charging to prevent the battery from
overheating when battery temperature exceeds the preset value.
2) When the battery temperature drops, the charger will restart automatically.
E05
1)
Discharging activities during charging
cycle.
2)
Battery low voltage detected during
charging
cycle.
3)
Output current is too high
(E05 will reappear even after unit reset).
1)
Make sure no discharging activity during chargingoperation.
2)
Reset charger (disconnect AC power and reconnect for a 2nd charge cycle).
3)
If E05 reappear within 10 minutes, please return charger to factory for repairing.
E06
Battery Voltage is too high.
Check and assure that the correct output battery voltage is connected.
E07
Address declaration failure
Return to the factory for repairing.
E08
Internal error in product.
Return to the factory for repairing.
E10
Relay Fault
Return to the factory for repairing.
E11
Battery error (battery damaged or
battery system error)
Replace battery
Fault Indicator
2
。
INTERLOCK
1
。
4
。
3
。
DC
OUTPUT
CANBUS/LED AC INPUT
@
Powering
everyday
everywhere!
%
Q
v
Q
A
Press
5 s: Change charging profile
10 s: Start EQ mode (Wet Battery)
Battery capacity % indicator
Battery voltage indicator
To change the charging profile, press & hold the Select button
for 5
seconds, then press the Select button to choose the
desired profile. Once selected, press & hold the Select key for
5 seconds, and the charging profile selection will be completed.
To start EQ mode, press & hold the Select button for 10
seconds, and display will show EQ mode. The next charging
cycle will go into EQ
mode. If you want to quit the EQ mode,
hold the Select button for 10 seconds. When display shows
OFF, the charger will quit the EQ mode.
Note:
Each operation interval is 5 seconds. If the operation
interval exceeds 5 seconds, it will automatically return to the
default setting.
2.
Common Mode(Default) & BMS Mode
Select button Charging current indicator
a. The charger enters BMS mode when being connected to lithium-ion battery through Can Bus;
b. For safety reason, the charger will flash "bnS" if being reconnected to Lead-acid battery under a BMS mode;
c. Press & hold the Select button for 3 seconds in BMS mode to release the curve number, that is, switch back to normal mode.Press & hold
the Select button for 1 seconds to choose the desired profile.
GPCC1
7
24
0-34V
0-1
7
A
5
78
W
GPCC
3012
0-
17
V
0-
30
A
5
10
W