Installation
10
Exhaust Duct
Yard Supply
Distance to the next upstream bent:
min. 3 duct diameters
Distance to the engine/turbo charger:
min. 10 duct diamters
Distance to the outlet:
min. 3 duct diamters
Distance to the next downstream bent:
min. 1 duct diameters
Sample to be drawn from the
inner 80% of the duct diameter.
On-Stack
Probe
Connection
Box
U
m
b
ili
c
a
l
C
o
rd
–
3.
0
m
le
ng
th
in
2
8
m
m
n
yl
on
c
on
du
it
Instrument Air
ISO 8573-1 class3
Yard Supply
Power Supply
24 VDC
Yard Supply
Signal Cable
Yard Supply
2
8
5
m
m
600 mm
Maintenance space: 700 mm
Scope of Supply per G
3620p
Stack Gas O2 Analyzing System
1pc Probe with Sensor
connected with a 3.0 m long umbilical cord (optional to 6m) to
1pc Sampling Control Board
connected with a 3.0 m long signal cable to
1pc G
36p
Oxygen Analyzer (to be installed in boiler panel)
600 × 285 × 180 mm
Flow
Flow
Zero Cal. Gas
optional
not required
G36p Oxygen Analyzer
Signal Cable standard 3 m & max. 6 m
Length/min. 5x0.34 sqmm shielded
Cable for Solenoid valves
3x1.5 sqmm
6
0
0
m
m
290 mm
Figure 3-2: Installation layout of the G3620p with G36p panel mounted analyzer