Green-Go GGO-SI2WR Скачать руководство пользователя страница 9

__________________________________________________________________________________ 
Green-GO Slim Audio Interface 2-Wire 

 Quick Start Guide

 

Device information 

 

Info 

 

Shows general information about the Slim Audio 2-Wire Interface

 

 

SN: xxx 

 

Serial number of the Slim Audio 2-Wire Interface 

 

SI 2wire 4a55  

 

Firmware information

 

 

 

SI 2wire 4a55    

 

Firmware version 

 

 

Jul 2 2018 

 

 

Date of firmware build 

 

 

09:32:09 

 

 

Time of firmware build 

 

IP: xxx.xxx.xxx.xx  

 

 

IP address of the Slim Audio 2-Wire Interface 

 

Mac: xx:xx:xx:xx:xx:xx  

 

Mac address of the Slim Audio 2-Wire Interface 

Reset All Settings  

 

Resets all IP, Audio, User and Channel settings   

(configuration file is not changed) 

 

 

Take the following steps to set up a 2-wire/party line connection; 

 

Connect the complete party line. 
Changing anything to the party line setup afterwards might require you to go 
through the setup steps once again. 

 

Switch off all mics on the party line 

 

Go to the setup menu and select Audio Line Setup 

 

Select the Mode for the party line type or line level 

 

Select Run Auto Null 

 

Select the Call mode as DC or AC or off 

 

Adjust the threshold in such a way that the Slim Audio Interface will not 
activate when no one is talking on the party line 

 

Adjust the To 2-wire and From 2-wire levels for final finetuning 

 

Select the desired user from the User Line 

 

Make sure that Auto Talk is enabled on the channel to send received audio 
(normally channel 1) 
 

NOTE:

 If you are experiencing an echo on the Green-GO system, it might be due to 

the Slim Audio Interface 2-Wire unit not correctly canceling out the audio sent onto 
the 2-Wire/party line and unintentionally sending it back into the system.

 

 

Setting up a 2-Wire connection

 

Содержание GGO-SI2WR

Страница 1: ...Slim Audio Interface 2 Wire Quick Start Guide...

Страница 2: ...__________________________________________________________________________________ Green GO Slim Audio Interface 2 Wire Quick Start Guide...

Страница 3: ...Green GO Slim Audio 2 Wire Interface enables you to integrate the basic analog party line systems into the GreenGO network complete with announcements and program audio Assign users or groups to up to...

Страница 4: ...hese buttons will let you either raise or lower the parameter s value The setup menu offers a range of different settings to modify your device The menu sections and their supplementary options are de...

Страница 5: ...Talk button enables talking pressing again disables talking Momentary Talk button must be kept pressed to enable talking Disabled Disable talking for this channel Listen On Listen Off Listen On Enabl...

Страница 6: ...om line Call Signal AC DC AC DC disabled Threshold Set the threshold level required for the input signal to be transmitted Available range is 45 to 20dB Hold Fast Med Long XLong To 2 wire Selectable r...

Страница 7: ...ed Local Connection Use local connection Remote Connection Use remote connection Password Set the password Generate password Generate a new password Remote Port Set the remote port to be used Remote I...

Страница 8: ...ddress Set the IP address to be used Netmask Set the netmask to be used Gateway Set the gateway to be used Save Save the current network setup Device options Device Options Flip Selects parts of the d...

Страница 9: ...mplete party line Changing anything to the party line setup afterwards might require you to go through the setup steps once again Switch off all mics on the party line Go to the setup menu and select...

Страница 10: ...s instructions Do not insert any objects through the ventilation slots of the unit as these could come in contact with live parts or could cause short circuits This could cause electric shock and or f...

Страница 11: ...2WR Which refer to this declaration are manufactured in the Netherlands and complies with the following product specifications and harmonized standards Safety LVD Low Voltage Directive 2014 35 EU EN62...

Отзывы: