12 / EN
PROBLEM SOLVING TIPS
Connected devices do not work, and the green power indicator does not light up.
CAUSE
SOLUTION
Battery defective or not functioning.
Check the battery, replace if necessary.
Reverse connection of negative and positive poles.
Correct the connection of the battery, the inverter might
have been damaged. Replace the fuse inside inverter
(outside warrianty cover, contact us before opening up
the inverter for warranty).
Untight cable connection.
Check the cables and the connection, tighten up the
wiring terminal.
The measured output current of the inverter is too low.
CAUSE
SOLUTION
The range of readings of the standard ampmeter is too
low.
Measure the „modified sine wave” with the „True-RMS
meter’ to get correct data.
Inverter current level too low.
Charge or replace the batteries.