Installation/ Operating Instruction 

for 7 day Fused Timer Spur Switch 

- Model: T205-C 

OPERATING INSTRUCTIONS

‘ON’ Indicator

Programme

Button

Time

Button

Fuse

Holder

Front Cable

Entry

Double Pole 

Isolation Switch

Reset

Button

‘+’ and ‘-’

Button

Dia.1

Dia.2

Dia.3

Dia.4

SETTING THE DAY OF WEEK 

AND TIME

Note: Time setting is 24 hour mode.

1. Press the ‘TIME’ button for 2 seconds. Day of 

week will start flashing (example shows 7 Day

setting Dia.3)

2. Use the ‘+’ or ‘-’ button to change the 

display to the correct day of the week.

3. Press the ‘TIME’ button and the hour digits will

flash.

(Dia.4)

4. Use the ‘+’ or ‘

-

’ button to set the hours.

5. Press the ‘TIME’ button and the minute digits will 

flash. (Dia.5)

6. Use the ‘+’ or ‘-’ button to set the minutes.

7. Press the ‘TIME’ button to save the setting 

and return to operating mode.

RESET THE DEVICE

1. To fully reset this unit press the recessed 

‘Reset’ button with a insulated blunt probe. 

2. A full display will show when the battery is 

charged, then revert to the default screen 

(       :       ). No display indicates that the 

battery requires charging for a minimum 3 

hour period. (Dia.2 - Full display)

Please read the instructions fully before attempting installation.

IMPORTANT

This unit should be installed by a competent person 

in accordance with the current IET Wiring Regulations. 

If in doubt consult a qualified electrician

.

• Timer Spur must not be mounted on a flammable surface.

• Ensure that the Timer Spur does not come into contact with any

combustible materials such as towels or bedding.

• Ensure at least a 300mm air space is allowed around the Timer Spur 

switch.

• A 12mm pattress is provided if extra spacing is required.

• Twin Earth terminal provided.

Note: Where earthing termination is required this must be connected to

a earth terminal as provided in a metal back box.

Dia.22

SUMMER MODE

1. In operating mode, pressing the ‘PROG’ 

and  ‘TIME’ (combination of buttons) to set

the summer mode. The clock will forward

on one  hour (showing the icon          

Dia.22).

Note: Battery is fully charged after 14.5 hours.

The non-replaceable, fully charged battery, will retain any program information

for a period of 700 hours should their be power loss or the unit switched off with

the double pole isolation switch.

Display is not visible during this period unless a button is pressed.

S

Note: Pressing the ‘PROG’ and ‘TIME’ (combinations of buttons) to exit the summer mode.

WIRING DIAGRAM

BATTERY BACK UP/LIFE

Display:

LCD

Working Voltage:

230V-50Hz

Rated Impulse Voltage: 2,500V

Operating Temp:

-5°C to +40°C

Operation:

Integrated Control

Max Load:

Resistive -

13A

Inductive -

6A

Isolation:

Double Pole Isolation

Switch

Conforms to:

BS 1363-4:1995+A4:2012,

BS EN 60730-1:2011, 

BS EN 60730-2-7:2010.

Working Environment: Indoor use only

Pollution Degree:

2

TECHNICAL INFORMATION

(Example: the clock will change to ‘11.00’, if the time is ‘10.00’ now

press “PROG’ and ‘TIME’.)

T205

Supply

Load

TIMER

13A Fuse

Isolation Switch

L

N

N

L

Issu

e n

o: 

70

46

98

WEST  ROAD  .  HARLOW

ESSEX . CM20 2BG . UK

[email protected]

www.greenbrook.co.uk

GUARANTEE

Your GreenBrook Fused Timer Spur Switch 

is guaranteed for 1 year from 

the date of purchase. 

This is in addition to your statutory rights.

PLEASE KEEP THESE INSTRUCTIONS 

SAFE FOR FUTURE REFERENCE