Please note, this safety extra low voltage (SELV) fan and its supply
controller must be installed by a fully qualified electrician in compliance
with current I.E.E and appropriate local regulations. In order to satisfy
current building regulations, correct fan selection and installation
practices must be applied.
P
PO
OS
SIIT
TIIO
ON
NIIN
NG
G T
TH
HE
E C
CO
ON
NT
TR
RO
OL
LL
LE
ER
R
It is a requirement of I.E.E. regulations that the controller is installed in a
position that is out of reach of a person using a bath or shower. Controller
models which do not have a humidistat may be fitted outside the room
containing the fan.
Humidistat models must be fitted inside the room containing the fan and
sited as high on the wall as possible, but not within
50
mm of the ceiling
and adjacent wall. All controller models must not be installed in a shower
cubicle, above a bath or where there is any possibility of liquid spray. They
must not be installed where the normal air temperature may exceed
40
°C
or in an area containing excessive levels of grease.
Fan controllers should not be covered with any heat insulating material, air
flow around the fitting should not be restricted. Note
50
mm minimum
distance to all adjacent surfaces. All models come complete with a patress
box but can be flush wall mounted by using a suitable
25
mm deep fixing
box.
INSTALLATION / OPERATING INSTRUCTIONS
FOR 12V FAN CONTROLLER RANGE
MODEL NUMBERS:
12
VFC /
12
VFCPC /
12
VFCT /
12
VFCTPC /
12
VFCHS /
12
VFCHSPC