GREEN BANK WG48200 Скачать руководство пользователя страница 6

09

4.3 ON / OFF or SOC Led (Mode or SOC)

BATTERY

 

MODE

ON/OFF

SOC

REMARK

GREEN

 

LED

RED

 

LED

 

LED1

   

LED2

   

LED3

   

LED4

 

POWER

 

OFF

OFF

OFF

OFF

OFF

OFF

OFF

POWER

 

ON

OFF

ON

ON

ON

ON

ON

STANDBY

OFF

OFF

SOC

SOC<10%(DEFAULT ):

 

LED1

 

FLASH

NORMAL

ON

OFF

RUNNING/SOC

SOC<10%(DEFAULT ):

 

LED1

 

FLASH

DISCHARGE

ON

OFF

SOC

SOC<10%(DEFAULT ):

 

LED1

 

FLASH

CHARGE

FLASH

OFF

RUNNING

LOW

 

POWER

FLASH

OFF

OFF

FAULT

OFF

ON

ON

OFF

OFF

OFF

BATTERY

 

VOLTAGE

 

HIGH

OFF

ON

OFF

OFF

BATTERY

 

VOLTAGE

 

LOW

ON

ON

OFF

OFF

CELL

 

VOLTAGE

 

HIGH

OFF

OFF

ON

OFF

CELL

 

VOLTAGE

 

LOW

ON

OFF

ON

OFF

CHARGING

 

CURRENT

 

HIGH

OFF

ON

ON

OFF

DISCHARGING

 

CURRENT

 

HIGH

ON

ON

ON

OFF

BMS

 

TEMPERATURE

 

HIGH

OFF

OFF

OFF

ON

BMS

 

TEMPERATURE

 

LOW

ON

OFF

OFF

ON

CELL

 

TEMPERATURE

 

HIGH

OFF

ON

OFF

ON

CELL

 

TEMPERATURE

 

LOW

ON

ON

OFF

ON

CURRENT

 

SENSOR

 

ABNOMAL

Sw1   SW2    SW3    SW4     Remarks

   0         0          0          0        means ID=0,communication address is0x00/0x10

   1         0          0          0        means ID=1,communication address is0x01

   0         1          0          0        means ID=2,communication address is0x02

   1         1          0          0        means ID=3,communication address is0x03

   0         0          1          0        means ID=4,communication address is0x04

   1         0          1          0        means ID=5,communication address is0x05

   0         1          1          0        means ID=6,communication address is0x06

   1         1          1          0        means ID=7,communication address is0x07

   0         0          0          1        means ID=8,communication address is0x08

   1         0          0          1        means ID=9,communication address is0x09

   0         1          0          1        means ID=10,communication address is0x0A

   1         1          0          1        means ID=11,communication address is0x0B

   0         0          1          1        means ID=12,communication address is0x0C

   1         0          1          1        means ID=13,communication address is0x0D

   0         1          1          1        means ID=14,communication address is0x0E

   1         1          1          1        means ID=15,communication address is0x0F

DIP switch SW5 Description

SW5

  1

  0

Remarks

means disconnect 
120Ω resistor

means connect 
120Ω resistor

Remark

: 1 in SW1-SW5 indicates ON status, and 0 indicates OFF status.      

Remark

: When multiple battery packs communicate, the last battery pack SW5 needs to be in the ON 

status, otherwise the communication may have interference.     
Remark

: When the battery pack ID is set to 0, it means stand-alone operation, and it is not necessary to 

detect whether the parallel condition is satisfied 

 

 

 

 

 

Remark

: When the battery pack ID is set to 1-15, it means that the parallel operation is required, and it is 

necessary to detect whether the parallel condition is satisfied 

 

 

 

 

 

Remark

: The parallel condition is that the difference between the battery voltage of the local battery and 

all the battery pack voltages is <3V, otherwise wait until the condition is satisfied

DIP switch SW1-SW4 Description 

4.4 DIP switch SW1-SW4 Description

08

4. OPERATION

Once the batteries are connected well, simply press On/Off button to enable the output of the battery pack.

1.Switch on: press On/Off button to switch on the battery, then the battery will do self-inspection before 
    enable output. The LED will show the SOC.
2.Switch off: press and hold On/Off button for 3 seconds, the battery will shut down directly.
   Description for Communication port

4.1 Switch On / Off

Picture                                               PIN             Description

1

2

3

4

5

6

7

8

Trigger-GND

Trigger-VCC

NC

COMM-GND

RS485-B

RS485-A

CANL

CANH

The SOC of the battery is shown by the LED

4.2 Description for LED

DIP SWITCH

1-4

5

Communication Address

Termination Resister

Note: The battery need to be fully charged for at least once in one month to ensure the accurate SOC 
calculation.

100%                            75%                            50%                         25%              Flashing SOC<10%

48V

 

Front view 

LiFePO4 Battery System

LiFePO4 Battery System