,QVWDOODWLRQDQG0DLQWHQDQFH
6HUYLFH0DQXDO
a
b
Procedure
Steps
10. Remove motor and cross flow blade
Remove the screws fixing motor clamp and
then remove the motor clamp.
Remove the screws at the connection place of
cross flow blade and motor; lift the motor and
cross flow blade upwards to remove them.
c
Remove the bearing holder sub-assy.
holder
sub-assy
bottom case
cross flow
motor clamp
motor
screws
screw